Testing and monitoring anabolic androgenic steroids in biological fluids is a key activity in anti-doping practices. In this study, a novel approach is proposed, based on dried urine microsampling through two different workflows: dried urine spots (DUS) and volumetric absorptive microsampling (VAMS). Both techniques can overcome some common drawbacks of urine sampling, such as analyte instability and storage and transportation problems. Using an original, validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, exogenous and endogenous unconjugated steroids were analysed. Despite the limitations of microsampling volume, good sensitivity was obtained (limit of quantitation <1.5 ng/mL for all analytes), with satisfactory precision (relative standard deviation <7.6%) and absolute recovery (>70.3%). Both microsampling platforms provide reliable results, in good agreement with those obtained from urine.
Protti M., Marasca C., Cirrincione M., Sberna A.E., Mandrioli R., Mercolini L. (2020). Dried urine microsampling coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the analysis of unconjugated anabolic androgenic steroids. MOLECULES, 25(14), 1-18 [10.3390/molecules25143210].
Dried urine microsampling coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the analysis of unconjugated anabolic androgenic steroids
Protti M.;Marasca C.;Cirrincione M.;Mandrioli R.;Mercolini L.
2020
Abstract
Testing and monitoring anabolic androgenic steroids in biological fluids is a key activity in anti-doping practices. In this study, a novel approach is proposed, based on dried urine microsampling through two different workflows: dried urine spots (DUS) and volumetric absorptive microsampling (VAMS). Both techniques can overcome some common drawbacks of urine sampling, such as analyte instability and storage and transportation problems. Using an original, validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, exogenous and endogenous unconjugated steroids were analysed. Despite the limitations of microsampling volume, good sensitivity was obtained (limit of quantitation <1.5 ng/mL for all analytes), with satisfactory precision (relative standard deviation <7.6%) and absolute recovery (>70.3%). Both microsampling platforms provide reliable results, in good agreement with those obtained from urine.File | Dimensione | Formato | |
---|---|---|---|
Molecules_25_2020_3210.pdf
accesso aperto
Tipo:
Versione (PDF) editoriale
Licenza:
Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione
1.86 MB
Formato
Adobe PDF
|
1.86 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.