Background: One of the most recent innovations in bone augmentation surgery is represented by computer- aided-design/computer-aided-manufacturing (CAD/CAM) customized titanium meshes, which can be used to restore vertical bone defects before implant-prosthetic rehabilitations. The aim of this study was to evaluate the effectiveness/reliability of this technique in a consecutive series of cases. Methods: Ten patients in need of bone augmentation before implant therapy were treated using CAD/CAM customized titanium meshes. A digital workflow was adopted to design virtual meshes on 3D bone models. Then, Direct Metal Laser Sintering (DMLS) technology was used to produce the titanium meshes, and vertical ridge augmentation was performed according to an established surgical protocol. Surgical complications, healing complications, vertical bone gain (VBG), planned bone volume (PBV), lacking bone volume (LBV), regenerated bone volume (RBV), average regeneration rate (RR) and implant success rate were evaluated. Results: All augmented sites were successfully restored with definitive implant-supported fixed partial dentures. Measurements showed an average VBG of 4.5 ± 1.8 mm at surgical re-entry. Surgical and healing complications 3 occurred in 30% and 10% of cases, respectively. Mean values of PBV, LBV, and RBV were 984, 92, and 892 mm , respectively. The average RR achieved was 89%. All 26 implants were successfully in function after 1 year of follow- up. Conclusions: The results of this study suggest that the bone augmentation by means of DMLS custom-made titanium meshes can be considered a reliable and effective technique in restoring vertical bone defects.

Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study / Cucchi, Alessandro; Bianchi, Alessandro; Calamai, Paolo; Rinaldi, Lisa; Mangano, Francesco; Vignudelli, Elisabetta; Corinaldesi, Giuseppe. - In: BMC ORAL HEALTH. - ISSN 1472-6831. - ELETTRONICO. - 20:1(2020), pp. 219.1-219.11. [10.1186/s12903-020-01205-4]

Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study

Cucchi, Alessandro;Vignudelli, Elisabetta;Corinaldesi, Giuseppe
2020

Abstract

Background: One of the most recent innovations in bone augmentation surgery is represented by computer- aided-design/computer-aided-manufacturing (CAD/CAM) customized titanium meshes, which can be used to restore vertical bone defects before implant-prosthetic rehabilitations. The aim of this study was to evaluate the effectiveness/reliability of this technique in a consecutive series of cases. Methods: Ten patients in need of bone augmentation before implant therapy were treated using CAD/CAM customized titanium meshes. A digital workflow was adopted to design virtual meshes on 3D bone models. Then, Direct Metal Laser Sintering (DMLS) technology was used to produce the titanium meshes, and vertical ridge augmentation was performed according to an established surgical protocol. Surgical complications, healing complications, vertical bone gain (VBG), planned bone volume (PBV), lacking bone volume (LBV), regenerated bone volume (RBV), average regeneration rate (RR) and implant success rate were evaluated. Results: All augmented sites were successfully restored with definitive implant-supported fixed partial dentures. Measurements showed an average VBG of 4.5 ± 1.8 mm at surgical re-entry. Surgical and healing complications 3 occurred in 30% and 10% of cases, respectively. Mean values of PBV, LBV, and RBV were 984, 92, and 892 mm , respectively. The average RR achieved was 89%. All 26 implants were successfully in function after 1 year of follow- up. Conclusions: The results of this study suggest that the bone augmentation by means of DMLS custom-made titanium meshes can be considered a reliable and effective technique in restoring vertical bone defects.
2020
Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design/computer-aided manufacturing (CAD/CAM) customized titanium meshes: a pilot study / Cucchi, Alessandro; Bianchi, Alessandro; Calamai, Paolo; Rinaldi, Lisa; Mangano, Francesco; Vignudelli, Elisabetta; Corinaldesi, Giuseppe. - In: BMC ORAL HEALTH. - ISSN 1472-6831. - ELETTRONICO. - 20:1(2020), pp. 219.1-219.11. [10.1186/s12903-020-01205-4]
Cucchi, Alessandro; Bianchi, Alessandro; Calamai, Paolo; Rinaldi, Lisa; Mangano, Francesco; Vignudelli, Elisabetta; Corinaldesi, Giuseppe
File in questo prodotto:
File Dimensione Formato  
Clinical and volumetric outcomes after vertical ridge augmentation using computer-aided-design:computer-aided manufacturing (CAD:CAM) customized titanium meshes- a pilot study.pdf

accesso aperto

Descrizione: ABSTRACT ARTICLE
Tipo: File Supplementare
Licenza: Licenza per accesso libero gratuito
Dimensione 162.41 kB
Formato Adobe PDF
162.41 kB Adobe PDF Visualizza/Apri
12903_2020_Article_1205.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 2.69 MB
Formato Adobe PDF
2.69 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/768273
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 29
social impact