Gastro-oesophageal reflux (GOR) is common in preterm infants. Combined multichannel intraluminal impedance and pH monitoring (pH-MII) is emerging as an useful tool to study both acid and non-acid GOR in this population. We aimed to highlight main advantages and limits of pH-MII in preterm infants and to test whether the inclusion of GOR episodes detected only by pH monitoring details better the features of GOR. Fifty-two symptomatic preterm infants underwent a 24-hour, continuous and simultaneous measurement of pH-MII. Each layout was analyzed using two different options: option 1 included GOR episodes detected by MII and then classified as acid or non-acid according to the associated pH change; option 2 included GOR episodes detected by MII and also GOR episodes detected only by pH sensor. By adopting option 1, a total number of 2834 GOR episodes was detected by MII: 2162 of them were characterized as non-acid and 672 were characterized as acid. The median (range) number of acid MII-GOR episodes was 10 (1-52); the median (range) number of non-acid MII-GOR episodes was 36.5 (2-119). Median (range) acid MII-GOR-bolus exposure index was 0.28% (0.02-2.73%); median (range) non-acid MII-GOR-bolus exposure index was 1.03% (0.06-38.15%). By adopting option 2, an average of 53.2 acid GOR episodes and an average of 11% oesophageal exposure to acid GOR more than by option 1 was detected. An accurate and detailed description of GOR in preterm infants can be obtained only by including in the analysis all acid GOR episodes detected by pH sensor.

Corvaglia L, Mariani E, Aceti A, Capretti MG, Ancora G, Faldella G. (2009). Combined oesophageal impedance-pH monitoring in preterm newborn: comparison of two options for layout analysis. NEUROGASTROENTEROLOGY AND MOTILITY, 21, 1027-1031 [10.1111/j.1365-2982.2009.01301.x].

Combined oesophageal impedance-pH monitoring in preterm newborn: comparison of two options for layout analysis.

CORVAGLIA, LUIGI TOMMASO;ACETI, ARIANNA;CAPRETTI, MARIA GRAZIA;FALDELLA, GIACOMO
2009

Abstract

Gastro-oesophageal reflux (GOR) is common in preterm infants. Combined multichannel intraluminal impedance and pH monitoring (pH-MII) is emerging as an useful tool to study both acid and non-acid GOR in this population. We aimed to highlight main advantages and limits of pH-MII in preterm infants and to test whether the inclusion of GOR episodes detected only by pH monitoring details better the features of GOR. Fifty-two symptomatic preterm infants underwent a 24-hour, continuous and simultaneous measurement of pH-MII. Each layout was analyzed using two different options: option 1 included GOR episodes detected by MII and then classified as acid or non-acid according to the associated pH change; option 2 included GOR episodes detected by MII and also GOR episodes detected only by pH sensor. By adopting option 1, a total number of 2834 GOR episodes was detected by MII: 2162 of them were characterized as non-acid and 672 were characterized as acid. The median (range) number of acid MII-GOR episodes was 10 (1-52); the median (range) number of non-acid MII-GOR episodes was 36.5 (2-119). Median (range) acid MII-GOR-bolus exposure index was 0.28% (0.02-2.73%); median (range) non-acid MII-GOR-bolus exposure index was 1.03% (0.06-38.15%). By adopting option 2, an average of 53.2 acid GOR episodes and an average of 11% oesophageal exposure to acid GOR more than by option 1 was detected. An accurate and detailed description of GOR in preterm infants can be obtained only by including in the analysis all acid GOR episodes detected by pH sensor.
2009
Corvaglia L, Mariani E, Aceti A, Capretti MG, Ancora G, Faldella G. (2009). Combined oesophageal impedance-pH monitoring in preterm newborn: comparison of two options for layout analysis. NEUROGASTROENTEROLOGY AND MOTILITY, 21, 1027-1031 [10.1111/j.1365-2982.2009.01301.x].
Corvaglia L; Mariani E; Aceti A; Capretti MG; Ancora G; Faldella G.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/76572
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 25
social impact