An array of proportional-resonant regulators is often used in shunt active power filters to control the grid currents and reduce the harmonic distortion caused by a distorting load. The voltage that is necessary to compensate for the current harmonics must be consistent with the available dc-link voltage. In this article, three adaptive algorithms for the exploitation of the dc-link voltage are developed and compared. These algorithms adaptively change the voltage saturation of each regulator to preserve the control capability of the fundamental component of the current when the available voltage is not enough to control the filter current. Simultaneously, they try to improve the quality of the grid current because the dc-link voltage of the active power filter is allocated to the regulators to compensate only the most significant harmonics. Some experimental results are shown to demonstrate the feasibility of the three algorithms.

Amerise A., Mengoni M., Rizzoli G., Zarri L., Tani A., Casadei D. (2020). Comparison of Three Voltage Saturation Algorithms in Shunt Active Power Filters with Selective Harmonic Control. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 56(3), 2762-2772 [10.1109/TIA.2020.2972853].

Comparison of Three Voltage Saturation Algorithms in Shunt Active Power Filters with Selective Harmonic Control

Mengoni M.;Rizzoli G.;Zarri L.
;
Tani A.;
2020

Abstract

An array of proportional-resonant regulators is often used in shunt active power filters to control the grid currents and reduce the harmonic distortion caused by a distorting load. The voltage that is necessary to compensate for the current harmonics must be consistent with the available dc-link voltage. In this article, three adaptive algorithms for the exploitation of the dc-link voltage are developed and compared. These algorithms adaptively change the voltage saturation of each regulator to preserve the control capability of the fundamental component of the current when the available voltage is not enough to control the filter current. Simultaneously, they try to improve the quality of the grid current because the dc-link voltage of the active power filter is allocated to the regulators to compensate only the most significant harmonics. Some experimental results are shown to demonstrate the feasibility of the three algorithms.
2020
Amerise A., Mengoni M., Rizzoli G., Zarri L., Tani A., Casadei D. (2020). Comparison of Three Voltage Saturation Algorithms in Shunt Active Power Filters with Selective Harmonic Control. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 56(3), 2762-2772 [10.1109/TIA.2020.2972853].
Amerise A.; Mengoni M.; Rizzoli G.; Zarri L.; Tani A.; Casadei D.
File in questo prodotto:
File Dimensione Formato  
IEEE_TIA_voltage_saturation_8988204_postprint.pdf

accesso aperto

Descrizione: Full paper - versione postprint
Tipo: Postprint
Licenza: Licenza per accesso libero gratuito
Dimensione 4.28 MB
Formato Adobe PDF
4.28 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/758455
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 10
social impact