This study evaluated the effect of mechanical cycling on the bond strength of zirconia posts to root dentin. Thirty single-rooted human teeth were transversally sectioned to a length of 16 mm. The canal preparation was performed with zirconia post system drills (CosmoPost, Ivoclar) to a depth of 12 mm. For post cementation, the canals were treated with total-etch, 3-steps All-Bond 2 (Bisco), and the posts were cemented with Duolink dual resin cement (Bisco). Three groups were formed (n = 10): G1 - control, no mechanical cycling; G2 - 20,000 mechanical cycles; G3 - 2,000,000 mechanical cycles. A 1.6-mm-thick punch induced loads of 50 N, at a 45° angle to the long axis of the specimens and at a frequency of 8 Hz directly on the posts. To evaluate the bond strengths, the specimens were sectioned perpendicular to the long axis of the teeth, generating 2-mm-thick slices, approximately (5 sections per teeth), which were subjected to the push-out test in a universal testing machine at a 1 mm/min crosshead speed. The push-out bond strength was affected by the mechanical cycling (1-way ANOVA, p = .0001). The results of the control group (7.7 ± 1.3 MPa) were statistically higher than those of G2 (3.9 ± 2.2 MPa) and G3 (3.3 ± 2.3 MPa). It was concluded that the mechani

G.A. GALHANO, R. MARQUEZ DE MELO, C.A. PAVANELLI, P. BALDISSARA, R. SCOTTI, L.F. VALANDRO, et al. (2008). Adhesive cementation of zirconia posts to root dentin: evaluation of the mechanical cycling effect. BRAZILIAN ORAL RESEARCH, 22(3), 264-269 [10.1590/s1806-83242008000300013].

Adhesive cementation of zirconia posts to root dentin: evaluation of the mechanical cycling effect.

BALDISSARA, PAOLO;SCOTTI, ROBERTO;
2008

Abstract

This study evaluated the effect of mechanical cycling on the bond strength of zirconia posts to root dentin. Thirty single-rooted human teeth were transversally sectioned to a length of 16 mm. The canal preparation was performed with zirconia post system drills (CosmoPost, Ivoclar) to a depth of 12 mm. For post cementation, the canals were treated with total-etch, 3-steps All-Bond 2 (Bisco), and the posts were cemented with Duolink dual resin cement (Bisco). Three groups were formed (n = 10): G1 - control, no mechanical cycling; G2 - 20,000 mechanical cycles; G3 - 2,000,000 mechanical cycles. A 1.6-mm-thick punch induced loads of 50 N, at a 45° angle to the long axis of the specimens and at a frequency of 8 Hz directly on the posts. To evaluate the bond strengths, the specimens were sectioned perpendicular to the long axis of the teeth, generating 2-mm-thick slices, approximately (5 sections per teeth), which were subjected to the push-out test in a universal testing machine at a 1 mm/min crosshead speed. The push-out bond strength was affected by the mechanical cycling (1-way ANOVA, p = .0001). The results of the control group (7.7 ± 1.3 MPa) were statistically higher than those of G2 (3.9 ± 2.2 MPa) and G3 (3.3 ± 2.3 MPa). It was concluded that the mechani
2008
G.A. GALHANO, R. MARQUEZ DE MELO, C.A. PAVANELLI, P. BALDISSARA, R. SCOTTI, L.F. VALANDRO, et al. (2008). Adhesive cementation of zirconia posts to root dentin: evaluation of the mechanical cycling effect. BRAZILIAN ORAL RESEARCH, 22(3), 264-269 [10.1590/s1806-83242008000300013].
G.A. GALHANO; R. MARQUEZ DE MELO; C.A. PAVANELLI;; P. BALDISSARA; R. SCOTTI; L.F. VALANDRO; M.A. BOTTINO
File in questo prodotto:
File Dimensione Formato  
Adhesive cementation of zirconia posts to root dentin.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale (CCBYNC)
Dimensione 210.68 kB
Formato Adobe PDF
210.68 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/74764
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 14
  • ???jsp.display-item.citation.isi??? ND
social impact