In the paper, the effects of the combination of electro-thermal stress, load cycles and thermal transients on polymer-insulated cable life are analyzed on the basis of Miner's cumulative damage law. Loss-of-life fractions within each portion of a stepwise-constant load cycle are calculated resorting to an electro-thermal life model holding for cable insulation subjected to voltage and temperature, considered within a probabilistic framework for associating life with residual reliability and failure probability. Thermal transients are treated by means of a well-known approach leading to a simplified but analytical expression for the temperature response of cable layers and soil to each current step. The application, relevant to high voltage ac XLPE-insulated cables with a stepwise-constant daily load cycle, shows that life is actually sensitive to load cycles, as well as to chosen life model and thermal transients, that should be considered for accurate cable life inference.

Effects of the combination of electro-thermal stress, load cycling and thermal transients on polymer-insulated high voltage ac cable life / G. Mazzanti. - ELETTRONICO. - (2005), pp. 1-8. (Intervento presentato al convegno 2005 IEEE Power Engineering Society General Meeting (IEEE PES GM 2005) tenutosi a San Francisco, California (USA) nel 12-16 giugno 2005).

Effects of the combination of electro-thermal stress, load cycling and thermal transients on polymer-insulated high voltage ac cable life

MAZZANTI, GIOVANNI
2005

Abstract

In the paper, the effects of the combination of electro-thermal stress, load cycles and thermal transients on polymer-insulated cable life are analyzed on the basis of Miner's cumulative damage law. Loss-of-life fractions within each portion of a stepwise-constant load cycle are calculated resorting to an electro-thermal life model holding for cable insulation subjected to voltage and temperature, considered within a probabilistic framework for associating life with residual reliability and failure probability. Thermal transients are treated by means of a well-known approach leading to a simplified but analytical expression for the temperature response of cable layers and soil to each current step. The application, relevant to high voltage ac XLPE-insulated cables with a stepwise-constant daily load cycle, shows that life is actually sensitive to load cycles, as well as to chosen life model and thermal transients, that should be considered for accurate cable life inference.
2005
Atti del 2005 IEEE Power Engineering Society General Meeting (IEEE PES GM 2005)
1
8
Effects of the combination of electro-thermal stress, load cycling and thermal transients on polymer-insulated high voltage ac cable life / G. Mazzanti. - ELETTRONICO. - (2005), pp. 1-8. (Intervento presentato al convegno 2005 IEEE Power Engineering Society General Meeting (IEEE PES GM 2005) tenutosi a San Francisco, California (USA) nel 12-16 giugno 2005).
G. Mazzanti
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/7470
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 1
social impact