The XENON1T experiment at the Laboratori Nazionali del Gran Sasso is the most sensitive direct detection experiment for dark matter in the form of weakly interacting particles (WIMPs) with masses above 6 GeV/c2 scattering off nuclei. The detector employs a dual-phase time projection chamber with 2.0 metric tons of liquid xenon in the target. A one metric ton×year exposure of science data was collected between October 2016 and February 2018. This article reports on the performance of the detector during this period and describes details of the data analysis that led to the most stringent exclusion limits on various WIMP-nucleon interaction models to date. In particular, signal reconstruction, event selection, and calibration of the detector response to nuclear and electronic recoils in XENON1T are discussed.

Aprile E., Aalbers J., Agostini F., Alfonsi M., Althueser L., Amaro F.D., et al. (2019). XENON1T dark matter data analysis: Signal reconstruction, calibration, and event selection. PHYSICAL REVIEW D, 100(5), 052014-052030 [10.1103/PhysRevD.100.052014].

XENON1T dark matter data analysis: Signal reconstruction, calibration, and event selection

Agostini F.
Membro del Collaboration Group
;
Di Gangi P.
Membro del Collaboration Group
;
Sartorelli G.
Funding Acquisition
;
Selvi M.;
2019

Abstract

The XENON1T experiment at the Laboratori Nazionali del Gran Sasso is the most sensitive direct detection experiment for dark matter in the form of weakly interacting particles (WIMPs) with masses above 6 GeV/c2 scattering off nuclei. The detector employs a dual-phase time projection chamber with 2.0 metric tons of liquid xenon in the target. A one metric ton×year exposure of science data was collected between October 2016 and February 2018. This article reports on the performance of the detector during this period and describes details of the data analysis that led to the most stringent exclusion limits on various WIMP-nucleon interaction models to date. In particular, signal reconstruction, event selection, and calibration of the detector response to nuclear and electronic recoils in XENON1T are discussed.
2019
Aprile E., Aalbers J., Agostini F., Alfonsi M., Althueser L., Amaro F.D., et al. (2019). XENON1T dark matter data analysis: Signal reconstruction, calibration, and event selection. PHYSICAL REVIEW D, 100(5), 052014-052030 [10.1103/PhysRevD.100.052014].
Aprile E.; Aalbers J.; Agostini F.; Alfonsi M.; Althueser L.; Amaro F.D.; Antochi V.C.; Arneodo F.; Baudis L.; Bauermeister B.; Bellagamba L.; Benabde...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/743608
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 56
  • ???jsp.display-item.citation.isi??? 49
social impact