The Unyvero molecular assay was tested for the clinical resolution of discordant results, evaluating its role in prosthetic joint infection diagnosis.

Objectives: The Unyvero molecular assay was tested for the clinical resolution of discordant results, evaluating its role in prosthetic joint infection diagnosis. Methods: Multiplex PCR was performed on 45 samples from prosthesis treatment (either sonication or dithiothreitol). Analytical performance was compared to that of biofilm culture using Musculoskeletal Infection Society criteria as gold standard. Results: Unyvero and biofilm culture showed similar agreement rates compared to the gold standard (34/43 and 32/43, respectively). Both methods showed six additional identifications compatible with true infection; five positive results from biofilm culture were deemed contaminations. Conclusions: The Unyvero system showed good performances and a significantly shorter turnaround time compared to cultural methods, presenting an added value to PJI diagnosis even when performed following a composite approach.

Zannoli, S., Sambri, A., Morotti, M., Tassinari, M., Torri, A., Bianchi, G., et al. (2021). Unyvero ITI® system for the clinical resolution of discrepancies in periprosthetic joint infection diagnosis. MUSCULOSKELETAL SURGERY, 105(1), 39-42 [10.1007/s12306-019-00626-x].

Unyvero ITI® system for the clinical resolution of discrepancies in periprosthetic joint infection diagnosis

Sambri, Andrea
;
Donati, Davide Maria;Sambri, Vittorio
2021

Abstract

Objectives: The Unyvero molecular assay was tested for the clinical resolution of discordant results, evaluating its role in prosthetic joint infection diagnosis. Methods: Multiplex PCR was performed on 45 samples from prosthesis treatment (either sonication or dithiothreitol). Analytical performance was compared to that of biofilm culture using Musculoskeletal Infection Society criteria as gold standard. Results: Unyvero and biofilm culture showed similar agreement rates compared to the gold standard (34/43 and 32/43, respectively). Both methods showed six additional identifications compatible with true infection; five positive results from biofilm culture were deemed contaminations. Conclusions: The Unyvero system showed good performances and a significantly shorter turnaround time compared to cultural methods, presenting an added value to PJI diagnosis even when performed following a composite approach.
2021
Zannoli, S., Sambri, A., Morotti, M., Tassinari, M., Torri, A., Bianchi, G., et al. (2021). Unyvero ITI® system for the clinical resolution of discrepancies in periprosthetic joint infection diagnosis. MUSCULOSKELETAL SURGERY, 105(1), 39-42 [10.1007/s12306-019-00626-x].
Zannoli, Silvia; Sambri, Andrea; Morotti, Manuela; Tassinari, Martina; Torri, Arianna; Bianchi, Giuseppe; De Paolis, Massimiliano; Donati, Davide Mari...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/734991
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact