The behaviour of multi-storey buildings braced with Cross-Laminated-Timber (CLT) cores and additional shear walls is examined based on numerical analyses of various 3-dimensional configurations. Two ways of calibrating numerical model are proposed according to codes and experimental test data respectively, including calibration of parameters that characterise connections between CLT panels in building cores and shear walls. Results of analyses of entire buildings are presented in terms of principal elastic periods, and base shear and up-lift forces. Discussion addresses primary issues associated with behaviour of such systems and modelling them.
Polastri A., Pozza L., Trutalli D., Scotta R., Smith I. (2014). Structural characterization of multi-storey buildings with CLT cores. World Conference on Timber Engineering (WCTE).
Structural characterization of multi-storey buildings with CLT cores
Pozza L.
;
2014
Abstract
The behaviour of multi-storey buildings braced with Cross-Laminated-Timber (CLT) cores and additional shear walls is examined based on numerical analyses of various 3-dimensional configurations. Two ways of calibrating numerical model are proposed according to codes and experimental test data respectively, including calibration of parameters that characterise connections between CLT panels in building cores and shear walls. Results of analyses of entire buildings are presented in terms of principal elastic periods, and base shear and up-lift forces. Discussion addresses primary issues associated with behaviour of such systems and modelling them.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.