Three innovative massive wooden shear-wall systems (Cross-Laminated-Glued Wall, Cross-Laminated-Stapled Wall, Layered Wall with dovetail inserts) were tested and their structural behaviour under seismic action was assessed with numerical simulations. The wall specimens differ mainly in the method used to assemble the layers of timber boards composing them. Quasi-static cyclic loading tests were carried out and then reproduced with a non-linear numerical model calibrated on the test results to estimate the most appropriate behaviour factor for each system. Non-linear dynamic simulations of 15 artificially generated seismic shocks showed that these systems have good dissipative capacity when correctly designed and that they can be assigned to the medium ductility class of Eurocode 8. This work also shows the influence of deformations in wooden panels and base connectors on the behaviour factor and dissipative capacity of the system.

Experimental and Numerical Analyses of New Massive Wooden Shear-Wall Systems / Pozza, Luca; Scotta, Roberto; Trutalli, Davide; Pinna, Mario; Polastri, Andrea; Bertoni, Paolo. - In: BUILDINGS. - ISSN 2075-5309. - ELETTRONICO. - 4:3(2014), pp. 355-374. [10.3390/buildings4030355]

Experimental and Numerical Analyses of New Massive Wooden Shear-Wall Systems

Pozza, Luca
;
2014

Abstract

Three innovative massive wooden shear-wall systems (Cross-Laminated-Glued Wall, Cross-Laminated-Stapled Wall, Layered Wall with dovetail inserts) were tested and their structural behaviour under seismic action was assessed with numerical simulations. The wall specimens differ mainly in the method used to assemble the layers of timber boards composing them. Quasi-static cyclic loading tests were carried out and then reproduced with a non-linear numerical model calibrated on the test results to estimate the most appropriate behaviour factor for each system. Non-linear dynamic simulations of 15 artificially generated seismic shocks showed that these systems have good dissipative capacity when correctly designed and that they can be assigned to the medium ductility class of Eurocode 8. This work also shows the influence of deformations in wooden panels and base connectors on the behaviour factor and dissipative capacity of the system.
2014
Experimental and Numerical Analyses of New Massive Wooden Shear-Wall Systems / Pozza, Luca; Scotta, Roberto; Trutalli, Davide; Pinna, Mario; Polastri, Andrea; Bertoni, Paolo. - In: BUILDINGS. - ISSN 2075-5309. - ELETTRONICO. - 4:3(2014), pp. 355-374. [10.3390/buildings4030355]
Pozza, Luca; Scotta, Roberto; Trutalli, Davide; Pinna, Mario; Polastri, Andrea; Bertoni, Paolo
File in questo prodotto:
File Dimensione Formato  
experimental and numerical analysis.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 4.56 MB
Formato Adobe PDF
4.56 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/732035
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? ND
social impact