Background & Aims Several non-invasive tests (NITs) have been developed to diagnose oesophageal varices (EV), including the recent Baveno VI criteria to rule out high-risk varices (HRV). Spleen stiffness measurement (SSM) with the standard FibroScan (R) (SSM@50Hz) has been evaluated. However, the EV grading could be underestimated because of a ceiling threshold (75 kPa) of the SSM@50Hz. The aims were to evaluate SSM by a novel spleen-dedicated FibroScan (R) (SSM@100Hz) for EV diagnosis compared with SSM@50Hz, other validated NITs and Baveno VI criteria. Methods This prospective multicentre study consecutively enrolled patients with chronic liver disease; blood data, endoscopy, liver stiffness measurement (LSM), SSM@50Hz and SSM@100Hz were collected. Results Two hundred and sixty patients met inclusion criteria. SSM@100Hz success rate was significantly higher than that of SSM@50Hz (92.5% vs 76.0%, P < .001). SSM@100Hz accuracy for the presence of EV (AUC = 0.728) and HRV (AUC = 0.756) was higher than in other NITs. SSM@100Hz AUC for large EV (0.782) was higher than SSM@50Hz (0.720, P = .027). AUC for HRV with SSM@100Hz (0.780) was higher than with LSM (0.615, P < .001). The spared endoscopy rate of Baveno VI criteria (8.1%) was significantly increased by the combination to SSM@50Hz (26.5%) or SSM@100Hz (38.9%, P < .001 vs others). The missed HRV rate was, respectively, 0% and 4.7% for combinations. Conclusions SSM@100Hz is a new performant non-invasive marker for EV and HRV providing a higher accuracy than SSM@50Hz and other NITs. The combination of Baveno VI criteria and SSM@100Hz significantly increased the spared endoscopy rate compared to Baveno VI criteria alone or combined with SSM@50Hz. Clinical trial number: NCT02180113.

Stefanescu H., Marasco G., Cales P., Fraquelli M., Rosselli M., Ganne-Carrie N., et al. (2020). A novel spleen-dedicated stiffness measurement by FibroScan® improves the screening of high-risk oesophageal varices. LIVER INTERNATIONAL, 40(1), 175-185 [10.1111/liv.14228].

A novel spleen-dedicated stiffness measurement by FibroScan® improves the screening of high-risk oesophageal varices

Stefanescu H.;Marasco G.
Writing – Original Draft Preparation
;
Ravaioli F.
Writing – Original Draft Preparation
;
Andreone P.;Mazzella G.;Festi D.
2020

Abstract

Background & Aims Several non-invasive tests (NITs) have been developed to diagnose oesophageal varices (EV), including the recent Baveno VI criteria to rule out high-risk varices (HRV). Spleen stiffness measurement (SSM) with the standard FibroScan (R) (SSM@50Hz) has been evaluated. However, the EV grading could be underestimated because of a ceiling threshold (75 kPa) of the SSM@50Hz. The aims were to evaluate SSM by a novel spleen-dedicated FibroScan (R) (SSM@100Hz) for EV diagnosis compared with SSM@50Hz, other validated NITs and Baveno VI criteria. Methods This prospective multicentre study consecutively enrolled patients with chronic liver disease; blood data, endoscopy, liver stiffness measurement (LSM), SSM@50Hz and SSM@100Hz were collected. Results Two hundred and sixty patients met inclusion criteria. SSM@100Hz success rate was significantly higher than that of SSM@50Hz (92.5% vs 76.0%, P < .001). SSM@100Hz accuracy for the presence of EV (AUC = 0.728) and HRV (AUC = 0.756) was higher than in other NITs. SSM@100Hz AUC for large EV (0.782) was higher than SSM@50Hz (0.720, P = .027). AUC for HRV with SSM@100Hz (0.780) was higher than with LSM (0.615, P < .001). The spared endoscopy rate of Baveno VI criteria (8.1%) was significantly increased by the combination to SSM@50Hz (26.5%) or SSM@100Hz (38.9%, P < .001 vs others). The missed HRV rate was, respectively, 0% and 4.7% for combinations. Conclusions SSM@100Hz is a new performant non-invasive marker for EV and HRV providing a higher accuracy than SSM@50Hz and other NITs. The combination of Baveno VI criteria and SSM@100Hz significantly increased the spared endoscopy rate compared to Baveno VI criteria alone or combined with SSM@50Hz. Clinical trial number: NCT02180113.
2020
Stefanescu H., Marasco G., Cales P., Fraquelli M., Rosselli M., Ganne-Carrie N., et al. (2020). A novel spleen-dedicated stiffness measurement by FibroScan® improves the screening of high-risk oesophageal varices. LIVER INTERNATIONAL, 40(1), 175-185 [10.1111/liv.14228].
Stefanescu H.; Marasco G.; Cales P.; Fraquelli M.; Rosselli M.; Ganne-Carrie N.; de Ledinghen V.; Ravaioli F.; Colecchia A.; Rusu C.; Andreone P.; Maz...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/718735
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 75
  • ???jsp.display-item.citation.isi??? 58
social impact