This paper proposes a model to determine the partial discharge inception voltage of magnet wires, including the effect of elevated temperatures, and shows its applicability to the complete range of wire geometries considered in IEC Standard 60317-13.
Lusuardi L., Cavallini A., De La Calle M.G., Martinez-Tarifa J.M., Robles G. (2019). Insulation design of low voltage electrical motors fed by PWM inverters. IEEE ELECTRICAL INSULATION MAGAZINE, 35(3), 7-15 [10.1109/MEI.2019.8689431].
Insulation design of low voltage electrical motors fed by PWM inverters
Lusuardi L.;Cavallini A.;
2019
Abstract
This paper proposes a model to determine the partial discharge inception voltage of magnet wires, including the effect of elevated temperatures, and shows its applicability to the complete range of wire geometries considered in IEC Standard 60317-13.File in questo prodotto: