Abstract Purpose Which total knee arthroplasty (TKA) design represents the better solution to restore a correct knee biomechanics is still debated. The aim of this study was to compare posterior stabilized (PS) and cruciate retaining (CR) version of the same TKA design (femoral component with an anatomic sagittal radius—J-curve design) by the use of dynamic Roentgen stereophotogrammetric analysis (RSA). The hypothesis was that the two models influence differently in vivo knee kinematic. Methods A cohort of 16 randomly selected patients was evaluated 9 months after surgery: Zimmer PERSONA® was implanted, eight with CR design and eight with PS design. The kinematic evaluations were performed using a Dynamic RSA (BI-STAND DRX 2) developed in our Institute, during the execution of the sit-to-stand motor task. The motion parameters were obtained using the Grood and Suntay decomposition and the low-point kinematics methods. Results PS TKA lateral femoral compartment had a wider anterior translation (17 ± 2 mm) than the medial one (11 ± 2 mm), while the two compartments of CR TKA showed a similar anterior translation (medial: 9 ± 2 mm/lateral: 11 ± 2 mm). T test for comparison between CR and PS TKA of antero-posterior translation showed a statistically significant difference (p < 0.05) in the flexion range between 15° and 40°. The CR prosthesis did not anteriorly translate during flexion. The PS design translated anteriorly showing a roll-forward mechanism during extension from 80° to 18° of flexion and a posterior translation from 18° to 0°. The same significant differences (p < 0.05) between the PS and CR groups were found comparing the low-point positions of the femoral condyles in the range of flexion between 25° and 40° for the medial compartment and between 15° and 25° for the lateral compartment. Conclusions Dynamic RSA was able to investigate for the first time in vivo the kinematic behaviour of PS and CR version of the same TKA J-curve design. PS type showed a medial pivot during sit-to-stand motion task, while the CR type showed a cylindrical movement.

Bontempi M, R.d.S.T. (2020). J‑curve design total knee arthroplasty: the posterior stabilized shows wider medial pivot compared to the cruciate retaining during chair raising. KNEE SURGERY, SPORTS TRAUMATOLOGY, ARTHROSCOPY, 28(9), 2883-2892 [10.1007/s00167-019-05645-6].

J‑curve design total knee arthroplasty: the posterior stabilized shows wider medial pivot compared to the cruciate retaining during chair raising

Bontempi M;Roberti di Sarsina T;Marcheggiani Muccioli GM;Pizza N;Cardinale U;Bragonzoni L;Zaffagnini S.
2020

Abstract

Abstract Purpose Which total knee arthroplasty (TKA) design represents the better solution to restore a correct knee biomechanics is still debated. The aim of this study was to compare posterior stabilized (PS) and cruciate retaining (CR) version of the same TKA design (femoral component with an anatomic sagittal radius—J-curve design) by the use of dynamic Roentgen stereophotogrammetric analysis (RSA). The hypothesis was that the two models influence differently in vivo knee kinematic. Methods A cohort of 16 randomly selected patients was evaluated 9 months after surgery: Zimmer PERSONA® was implanted, eight with CR design and eight with PS design. The kinematic evaluations were performed using a Dynamic RSA (BI-STAND DRX 2) developed in our Institute, during the execution of the sit-to-stand motor task. The motion parameters were obtained using the Grood and Suntay decomposition and the low-point kinematics methods. Results PS TKA lateral femoral compartment had a wider anterior translation (17 ± 2 mm) than the medial one (11 ± 2 mm), while the two compartments of CR TKA showed a similar anterior translation (medial: 9 ± 2 mm/lateral: 11 ± 2 mm). T test for comparison between CR and PS TKA of antero-posterior translation showed a statistically significant difference (p < 0.05) in the flexion range between 15° and 40°. The CR prosthesis did not anteriorly translate during flexion. The PS design translated anteriorly showing a roll-forward mechanism during extension from 80° to 18° of flexion and a posterior translation from 18° to 0°. The same significant differences (p < 0.05) between the PS and CR groups were found comparing the low-point positions of the femoral condyles in the range of flexion between 25° and 40° for the medial compartment and between 15° and 25° for the lateral compartment. Conclusions Dynamic RSA was able to investigate for the first time in vivo the kinematic behaviour of PS and CR version of the same TKA J-curve design. PS type showed a medial pivot during sit-to-stand motion task, while the CR type showed a cylindrical movement.
2020
Bontempi M, R.d.S.T. (2020). J‑curve design total knee arthroplasty: the posterior stabilized shows wider medial pivot compared to the cruciate retaining during chair raising. KNEE SURGERY, SPORTS TRAUMATOLOGY, ARTHROSCOPY, 28(9), 2883-2892 [10.1007/s00167-019-05645-6].
Bontempi M, Roberti di Sarsina T, Marcheggiani Muccioli GM, Pizza N, Cardinale U, Bragonzoni L, Zaffagnini S.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/717970
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact