In this clinical case was investigated the basic principles of digital workflow and the surgical steps of a novel type of custom-made titanium mesh (Ti-mesh), validated this surgical approach for bone augmentation in an edentulous atrophic maxilla, and analyzed the stability of the augmented bone after 1 year of follow-up
Custom-made titanium mesh for maxillary bone augmentation with immediate implants and delayed loading
Cucchi A.;Lizio G.;Corinaldesi G.
2019
Abstract
In this clinical case was investigated the basic principles of digital workflow and the surgical steps of a novel type of custom-made titanium mesh (Ti-mesh), validated this surgical approach for bone augmentation in an edentulous atrophic maxilla, and analyzed the stability of the augmented bone after 1 year of follow-upFile in questo prodotto:
Eventuali allegati, non sono esposti
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.