This is a prospective interventional clinical study evaluating intraocular inflammation developed after Ultrasound Cyclo Plasty (UCP) for the treatment of glaucoma. Eighteen eyes of 18 patients were treated with UCP second-generation probes (Eye OP1). After treatment, the mean intraocular pressure (IOP) significantly decreased from 26.8±7.2 to 18.8±6.1 mm Hg at day 1 and to 14.7±3.4 mm Hg at month 6 (all P<0.001). Mean laser flare-cell photometry value steeply increased after surgery from 12.1±7.5 to 64.1±53.9 ph/ms (P=0.001) at day 1, and then progressively decreased to respectively 60.6±49.7 at day 7, 43.5±38.5 at day 14 and 28.2±18.3 at month 1 (all P<0.05), returning at levels similar to baseline ones at month 3 and month 6 (respectively 16.7±6.2 and 12.8±10.2, both P>0.05). A significant negative correlation was found between postoperative increase of aqueous flare values and anterior chamber depth (R=-0.568, P=0.014). This timeframe may be considered reasonable for repeating UCP treatment, when required.

Pellegrini M, S.S. (2019). Intraocular inflammation after Ultrasound Cyclo Plasty for the treatment of glaucoma. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 12(2), 338-341 [10.18240/ijo.2019.02.23].

Intraocular inflammation after Ultrasound Cyclo Plasty for the treatment of glaucoma

Pellegrini M;Sebastiani S;Giannaccare G
Writing – Review & Editing
;
Campos EC
2019

Abstract

This is a prospective interventional clinical study evaluating intraocular inflammation developed after Ultrasound Cyclo Plasty (UCP) for the treatment of glaucoma. Eighteen eyes of 18 patients were treated with UCP second-generation probes (Eye OP1). After treatment, the mean intraocular pressure (IOP) significantly decreased from 26.8±7.2 to 18.8±6.1 mm Hg at day 1 and to 14.7±3.4 mm Hg at month 6 (all P<0.001). Mean laser flare-cell photometry value steeply increased after surgery from 12.1±7.5 to 64.1±53.9 ph/ms (P=0.001) at day 1, and then progressively decreased to respectively 60.6±49.7 at day 7, 43.5±38.5 at day 14 and 28.2±18.3 at month 1 (all P<0.05), returning at levels similar to baseline ones at month 3 and month 6 (respectively 16.7±6.2 and 12.8±10.2, both P>0.05). A significant negative correlation was found between postoperative increase of aqueous flare values and anterior chamber depth (R=-0.568, P=0.014). This timeframe may be considered reasonable for repeating UCP treatment, when required.
2019
Pellegrini M, S.S. (2019). Intraocular inflammation after Ultrasound Cyclo Plasty for the treatment of glaucoma. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 12(2), 338-341 [10.18240/ijo.2019.02.23].
Pellegrini M, Sebastiani S, Giannaccare G, Campos EC
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/711968
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 16
social impact