Among the large number of chiroptical sensors that have been developed to date, few allow rational determination of the absolute configuration of chiral substrates together with quantitative ee analysis. We have prepared and tested stereodynamic N-aryl aminobenzaldehyde sensors that bind chiral amines via Schiff base formation. The covalent binding of the amine substrate generates a conformational bias in the chromophoric sensor moiety which results in characteristic CD signals. Computational analysis revealed that CD prediction of the sign of the Cotton effect and thus determination of the absolute configuration of the substrate becomes practical with a sterically crowded sensor design because the number of conformations to be considered is largely reduced and the chiroptical sensor response is less sensitive to conformational equilibria. The amplitude of the measured CD signal can be used for quantitative ee analysis of nonracemic amine samples with the help of a calibration curve.

Pilicer S.L., Mancinelli M., Mazzanti A., Wolf C. (2019). Predictive chirality sensing: Via Schiff base formation. ORGANIC & BIOMOLECULAR CHEMISTRY, 17(27), 6699-6705 [10.1039/c9ob01265f].

Predictive chirality sensing: Via Schiff base formation

Mancinelli M.;Mazzanti A.
;
2019

Abstract

Among the large number of chiroptical sensors that have been developed to date, few allow rational determination of the absolute configuration of chiral substrates together with quantitative ee analysis. We have prepared and tested stereodynamic N-aryl aminobenzaldehyde sensors that bind chiral amines via Schiff base formation. The covalent binding of the amine substrate generates a conformational bias in the chromophoric sensor moiety which results in characteristic CD signals. Computational analysis revealed that CD prediction of the sign of the Cotton effect and thus determination of the absolute configuration of the substrate becomes practical with a sterically crowded sensor design because the number of conformations to be considered is largely reduced and the chiroptical sensor response is less sensitive to conformational equilibria. The amplitude of the measured CD signal can be used for quantitative ee analysis of nonracemic amine samples with the help of a calibration curve.
2019
Pilicer S.L., Mancinelli M., Mazzanti A., Wolf C. (2019). Predictive chirality sensing: Via Schiff base formation. ORGANIC & BIOMOLECULAR CHEMISTRY, 17(27), 6699-6705 [10.1039/c9ob01265f].
Pilicer S.L.; Mancinelli M.; Mazzanti A.; Wolf C.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/711386
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact