PurposeTo compare post-operative recovery of prosthetic hip surgery patients with or without the implementation of iron supplementation with a new highly absorbable oral iron formulation.MethodsObservational retrospective quality improvement assessment conducted on patients who had undergone elective prosthetic hip surgery (first implant) with ferritin <100mcg/dl and Hb values between 13 and 14g/dl for men and 12g/dl and 13.5g/dl for women, or having ferritin levels >100mcg/dl but C-reactive protein (CRP) >3mg/l and transferrin saturation (TSAT) <20%, which together are suggestive of functional iron deficiency. The analysis compared a group of non-anaemic patients having ferritin levels >100mcg/l to two groups of patients with iron deficiency, of which only one received iron supplementation. Measurements included haemoglobin levels, length of hospital stay, and number of transfused patients/blood units.ResultsPatients with iron deficiency supplemented with Sideral (R) Forte compared to non-supplemented patients showed a smaller decline in post-operative Hb (9.71.24g/dl vs 8.4 +/- 0.6g/dl), required shorter hospital stay (4 vs 6.5days) and less blood transfusions (0 in the iron-supplemented group vs 7units in the non-iron-supplemented group), yielding an overall savings of 1763.25 Euro/patient.Conclusions p id=Par4 Pre-operative sucrosomial iron supplementation at least 4weeks prior to elective surgery in non-anaemic patients limits the drop in post-operative Hb levels, determining higher post-operative haemoglobin, quicker post-surgical recovery, shorter hospitalisation, and decreased surgery-related costs.

Improved patient blood management and cost saving in hip replacement surgery through the implementation of pre-operative Sucrosomial® iron supplementation: a quality improvement assessment study / Scardino M.; Di Matteo B.; Martorelli F.; Tanzi D.; Kon E.; D'Amato T.. - In: INTERNATIONAL ORTHOPAEDICS. - ISSN 0341-2695. - ELETTRONICO. - 43:1(2019), pp. 39-46. [10.1007/s00264-018-4149-7]

Improved patient blood management and cost saving in hip replacement surgery through the implementation of pre-operative Sucrosomial® iron supplementation: a quality improvement assessment study

Di Matteo B.
;
Kon E.;
2019

Abstract

PurposeTo compare post-operative recovery of prosthetic hip surgery patients with or without the implementation of iron supplementation with a new highly absorbable oral iron formulation.MethodsObservational retrospective quality improvement assessment conducted on patients who had undergone elective prosthetic hip surgery (first implant) with ferritin <100mcg/dl and Hb values between 13 and 14g/dl for men and 12g/dl and 13.5g/dl for women, or having ferritin levels >100mcg/dl but C-reactive protein (CRP) >3mg/l and transferrin saturation (TSAT) <20%, which together are suggestive of functional iron deficiency. The analysis compared a group of non-anaemic patients having ferritin levels >100mcg/l to two groups of patients with iron deficiency, of which only one received iron supplementation. Measurements included haemoglobin levels, length of hospital stay, and number of transfused patients/blood units.ResultsPatients with iron deficiency supplemented with Sideral (R) Forte compared to non-supplemented patients showed a smaller decline in post-operative Hb (9.71.24g/dl vs 8.4 +/- 0.6g/dl), required shorter hospital stay (4 vs 6.5days) and less blood transfusions (0 in the iron-supplemented group vs 7units in the non-iron-supplemented group), yielding an overall savings of 1763.25 Euro/patient.Conclusions p id=Par4 Pre-operative sucrosomial iron supplementation at least 4weeks prior to elective surgery in non-anaemic patients limits the drop in post-operative Hb levels, determining higher post-operative haemoglobin, quicker post-surgical recovery, shorter hospitalisation, and decreased surgery-related costs.
2019
Improved patient blood management and cost saving in hip replacement surgery through the implementation of pre-operative Sucrosomial® iron supplementation: a quality improvement assessment study / Scardino M.; Di Matteo B.; Martorelli F.; Tanzi D.; Kon E.; D'Amato T.. - In: INTERNATIONAL ORTHOPAEDICS. - ISSN 0341-2695. - ELETTRONICO. - 43:1(2019), pp. 39-46. [10.1007/s00264-018-4149-7]
Scardino M.; Di Matteo B.; Martorelli F.; Tanzi D.; Kon E.; D'Amato T.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/703664
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 13
social impact