For the accurate statistical assessment of the lightning performance of distribution lines one needs to take into account the presence of protection devices such as surge arresters and shielding wire/neutral groundings. Indeed, the presence of those devices can significantly modify the indirect lightning response of the overhead line and, therefore, the relevant lightning performance. In particular, this paper aims at investigating the impact of the presence of surge arresters on the indirect lightning performance of overhead distribution lines having realistic configuration. Specifically, reference is made to typical Italian distribution lines. The investigation is performed with the help of a statistical procedure developed by the authors – based on the Monte Carlo method and of the use of an accurate modelling/calculation tool for the induced surges – that has been recently compared with one proposed in the IEEE 1410 Std for the same purpose, and shown to be more complete and suitable for the problem of interest. The paper also aims at investigating the influence of the presence of surge arresters on the indirect lightning surges transferred through power transformers. Such an additional investigation is performed by means of a suitable high-frequency power transformer mode integrated with the lightning-induced computation tool.

A. Borghetti, F. Napolitano, C.A. Nucci, M. Paolone (2008). On the Mitigation Effect of Surge Arresters on the Lightning Performance of Overhead Distribution Lines. DUBROVNIK : D. Dvorki.

On the Mitigation Effect of Surge Arresters on the Lightning Performance of Overhead Distribution Lines

BORGHETTI, ALBERTO;NAPOLITANO, FABIO;NUCCI, CARLO ALBERTO;PAOLONE, MARIO
2008

Abstract

For the accurate statistical assessment of the lightning performance of distribution lines one needs to take into account the presence of protection devices such as surge arresters and shielding wire/neutral groundings. Indeed, the presence of those devices can significantly modify the indirect lightning response of the overhead line and, therefore, the relevant lightning performance. In particular, this paper aims at investigating the impact of the presence of surge arresters on the indirect lightning performance of overhead distribution lines having realistic configuration. Specifically, reference is made to typical Italian distribution lines. The investigation is performed with the help of a statistical procedure developed by the authors – based on the Monte Carlo method and of the use of an accurate modelling/calculation tool for the induced surges – that has been recently compared with one proposed in the IEEE 1410 Std for the same purpose, and shown to be more complete and suitable for the problem of interest. The paper also aims at investigating the influence of the presence of surge arresters on the indirect lightning surges transferred through power transformers. Such an additional investigation is performed by means of a suitable high-frequency power transformer mode integrated with the lightning-induced computation tool.
2008
Proceedings of the Cigre International Colloquium: Application of Line Surge Arresters in Power Distribution and Transmission Systems
1
8
A. Borghetti, F. Napolitano, C.A. Nucci, M. Paolone (2008). On the Mitigation Effect of Surge Arresters on the Lightning Performance of Overhead Distribution Lines. DUBROVNIK : D. Dvorki.
A. Borghetti; F. Napolitano; C.A. Nucci; M. Paolone
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/69636
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact