During surgical procedures involving the mandible, preserving the inferior alveolar nerve (IAN) may be preferable for benign tumours. In this prospective pilot study, we report our experience on the use of a Rapid Inferior Alveolar nerve Customised Salvage (RICS) template. Virtual surgical planning (VSP) of the template is based on a 3D model obtained from the elaboration of DICOM files of the preoperative CT scan. Five patients affected by benign mandibular pathology were included. A total of 7 IANs were exteriorised. The average time of exteriorisation was 23 minutes. All exteriorisations were performed successfully and no damage to the neuro-vascular bundle occurred. All patients showed complete recovery of sensitivity of the IAN within 7 weeks after surgical procedure. In conclusion, RICS template seems to allow faster and safer exteriorisation of the IAN.

Use of a CAD-CAM inferior alveolar nerve salvage template during mandibular resection for benign lesions / Ricotta F.; Battaglia S.; Sandi A.; Pizzigallo A.; Marchetti C.; Tarsitano A.. - In: ACTA OTORHINOLARYNGOLOGICA ITALICA. - ISSN 1827-675X. - STAMPA. - 39:2(2019), pp. 117-121. [10.14639/0392-100X-2408]

Use of a CAD-CAM inferior alveolar nerve salvage template during mandibular resection for benign lesions

Marchetti C.;Tarsitano A.
2019

Abstract

During surgical procedures involving the mandible, preserving the inferior alveolar nerve (IAN) may be preferable for benign tumours. In this prospective pilot study, we report our experience on the use of a Rapid Inferior Alveolar nerve Customised Salvage (RICS) template. Virtual surgical planning (VSP) of the template is based on a 3D model obtained from the elaboration of DICOM files of the preoperative CT scan. Five patients affected by benign mandibular pathology were included. A total of 7 IANs were exteriorised. The average time of exteriorisation was 23 minutes. All exteriorisations were performed successfully and no damage to the neuro-vascular bundle occurred. All patients showed complete recovery of sensitivity of the IAN within 7 weeks after surgical procedure. In conclusion, RICS template seems to allow faster and safer exteriorisation of the IAN.
2019
Use of a CAD-CAM inferior alveolar nerve salvage template during mandibular resection for benign lesions / Ricotta F.; Battaglia S.; Sandi A.; Pizzigallo A.; Marchetti C.; Tarsitano A.. - In: ACTA OTORHINOLARYNGOLOGICA ITALICA. - ISSN 1827-675X. - STAMPA. - 39:2(2019), pp. 117-121. [10.14639/0392-100X-2408]
Ricotta F.; Battaglia S.; Sandi A.; Pizzigallo A.; Marchetti C.; Tarsitano A.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/691607
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact