This study evaluated the outcomes of computer-aided design–computer-aided machining (CAD-CAM)–customized titanium mesh used for prosthetically guided bone augmentation related to the occlusion-driven implant position, to the vertical bone volume gain of the mandible and maxilla, and to complications, such as mesh exposure. Nine patients scheduled for bone augmentation of atrophic sites were treated with custom titanium mesh and particulate bone grafts with autologous bone and anorganic bovine bone in a 1:1 ratio prior to implant surgery. The bone volume needed to augment was virtually projected based on implant position, width, and length, and the mesh design was programmed for the necessary retaining screws. After 6 to 8 months, bone augmentations of 1.72 to 4.1 mm (mean: 3.83 mm) for the mandibular arch and 2.14 to 6.88 mm (mean: 3.95 mm) for the maxilla were registered on cone-beam computerized tomography. Mesh premature (within 4 to 6 weeks) exposure was observed in 3 cases and delayed (after 4 to 6 weeks) in 3 other cases. One titanium mesh was removed before the programmed time but in all augmented sites was possible implant insertion. No complication occurred during prosthetic follow-up. Using CAD-CAM technology for prosthetically guided bone augmentation showed important postoperative morbidity of mesh exposure (66%). Because of this high prevalence of mesh exposure and the potential infection that could affect the expected bone augmentation, this study suggests a cautious approach to this procedure when designing the titanium mesh, to avoid flap tension that may cause mucosal rupture.

Ciocca, L., Lizio, G., Baldissara, P., Sambuco, A., Scotti, R., Corinaldesi, G. (2018). Prosthetically CAD-CAM–guided bone augmentation of atrophic jaws using customized titanium mesh: Preliminary results of an open prospective study. JOURNAL OF ORAL IMPLANTOLOGY, 44(2), 131-137 [10.1563/aaid-joi-D-17-00125].

Prosthetically CAD-CAM–guided bone augmentation of atrophic jaws using customized titanium mesh: Preliminary results of an open prospective study

Ciocca, Leonardo;Lizio, Giuseppe;Baldissara, Paolo;Scotti, Roberto;Corinaldesi, Giuseppe
2018

Abstract

This study evaluated the outcomes of computer-aided design–computer-aided machining (CAD-CAM)–customized titanium mesh used for prosthetically guided bone augmentation related to the occlusion-driven implant position, to the vertical bone volume gain of the mandible and maxilla, and to complications, such as mesh exposure. Nine patients scheduled for bone augmentation of atrophic sites were treated with custom titanium mesh and particulate bone grafts with autologous bone and anorganic bovine bone in a 1:1 ratio prior to implant surgery. The bone volume needed to augment was virtually projected based on implant position, width, and length, and the mesh design was programmed for the necessary retaining screws. After 6 to 8 months, bone augmentations of 1.72 to 4.1 mm (mean: 3.83 mm) for the mandibular arch and 2.14 to 6.88 mm (mean: 3.95 mm) for the maxilla were registered on cone-beam computerized tomography. Mesh premature (within 4 to 6 weeks) exposure was observed in 3 cases and delayed (after 4 to 6 weeks) in 3 other cases. One titanium mesh was removed before the programmed time but in all augmented sites was possible implant insertion. No complication occurred during prosthetic follow-up. Using CAD-CAM technology for prosthetically guided bone augmentation showed important postoperative morbidity of mesh exposure (66%). Because of this high prevalence of mesh exposure and the potential infection that could affect the expected bone augmentation, this study suggests a cautious approach to this procedure when designing the titanium mesh, to avoid flap tension that may cause mucosal rupture.
2018
Ciocca, L., Lizio, G., Baldissara, P., Sambuco, A., Scotti, R., Corinaldesi, G. (2018). Prosthetically CAD-CAM–guided bone augmentation of atrophic jaws using customized titanium mesh: Preliminary results of an open prospective study. JOURNAL OF ORAL IMPLANTOLOGY, 44(2), 131-137 [10.1563/aaid-joi-D-17-00125].
Ciocca, Leonardo*; Lizio, Giuseppe; Baldissara, Paolo; Sambuco, Alessandro; Scotti, Roberto; Corinaldesi, Giuseppe
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/674364
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 45
social impact