In this paper the conducted emissions generated by a DC/DC power converter system in the 2-150 kHz frequency range are studied in both time and frequency domains. Measurement and evaluation of the conducted emissions are carried out to assess the level of the emissions of the system with reference to the existing standards and to point out which measurement settings may have an impact on the measurement results. A prototype of a DC/DC battery charger for electric vehicles was used in the experiments. The results show that the DC/DC power converter system may not result in being compliant to some of the existing standards in the frequency range 2-150 kHz and that measurement settings may affect significantly the evaluation of the conducted emissions-

Measurement and Evaluation of the Conducted Emissions of a DC/DC Power Converter in the Frequency Range 2-150 kHz / Sandrolini, Leonardo; Thomas, David W.P.; Sumner, Mark; Rose, Christopher. - ELETTRONICO. - (2018), pp. 8495199.345-8495199.350. (Intervento presentato al convegno 2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity, EMC, SI and PI 2018 tenutosi a Long Beach, USA nel July 30 - Aug. 3, 2018) [10.1109/EMCSI.2018.8495199].

Measurement and Evaluation of the Conducted Emissions of a DC/DC Power Converter in the Frequency Range 2-150 kHz

Sandrolini, Leonardo
;
2018

Abstract

In this paper the conducted emissions generated by a DC/DC power converter system in the 2-150 kHz frequency range are studied in both time and frequency domains. Measurement and evaluation of the conducted emissions are carried out to assess the level of the emissions of the system with reference to the existing standards and to point out which measurement settings may have an impact on the measurement results. A prototype of a DC/DC battery charger for electric vehicles was used in the experiments. The results show that the DC/DC power converter system may not result in being compliant to some of the existing standards in the frequency range 2-150 kHz and that measurement settings may affect significantly the evaluation of the conducted emissions-
2018
Proceedings 2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity, EMC, SI and PI 2018
345
350
Measurement and Evaluation of the Conducted Emissions of a DC/DC Power Converter in the Frequency Range 2-150 kHz / Sandrolini, Leonardo; Thomas, David W.P.; Sumner, Mark; Rose, Christopher. - ELETTRONICO. - (2018), pp. 8495199.345-8495199.350. (Intervento presentato al convegno 2018 IEEE Symposium on Electromagnetic Compatibility, Signal Integrity and Power Integrity, EMC, SI and PI 2018 tenutosi a Long Beach, USA nel July 30 - Aug. 3, 2018) [10.1109/EMCSI.2018.8495199].
Sandrolini, Leonardo; Thomas, David W.P.; Sumner, Mark; Rose, Christopher
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/673628
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 12
social impact