Conductive atomic force microscopy (C-AFM) has been extensively used for making measurements of electrical properties of nanostructures, devices and multiphase materials. Despite its wide use, the mechanical and electrical interactions at the nanoscale between the tip and the sample surface are not yet well understood. These phenomena should be carefully studied and modeled in order to avoid significant measurement artifacts. In the present contribution a study of the interactions occurring between conductive tips and the surface of nanocrystalline silicon thin films that lead to measurement artifacts is presented. A significant deterioration of the tip coating was detected after a few maps, resulting in meaningless maps. The features of the map obtained dramatically depend on the tip coating characteristics and on the load conditions. Moreover, under a constant bias voltage, the electrical current passing through the tip–sample junction degenerates strongly with time. These phenomena were interpreted by considering the effect of strong electric fields present during C-AFM experiments.

D. Cavalcoli, M. Rossi., A. Tomasi, A.Cavallini (2009). Degeneracy and instability of nanocontacts between conductive tips and hydrogenated nanocrystalline Si surfaces in conductive atomic force microscopy. NANOTECHNOLOGY, 20, 045702-045708 [10.1088/0957-4484/20/4/045702].

Degeneracy and instability of nanocontacts between conductive tips and hydrogenated nanocrystalline Si surfaces in conductive atomic force microscopy

CAVALCOLI, DANIELA;CAVALLINI, ANNA
2009

Abstract

Conductive atomic force microscopy (C-AFM) has been extensively used for making measurements of electrical properties of nanostructures, devices and multiphase materials. Despite its wide use, the mechanical and electrical interactions at the nanoscale between the tip and the sample surface are not yet well understood. These phenomena should be carefully studied and modeled in order to avoid significant measurement artifacts. In the present contribution a study of the interactions occurring between conductive tips and the surface of nanocrystalline silicon thin films that lead to measurement artifacts is presented. A significant deterioration of the tip coating was detected after a few maps, resulting in meaningless maps. The features of the map obtained dramatically depend on the tip coating characteristics and on the load conditions. Moreover, under a constant bias voltage, the electrical current passing through the tip–sample junction degenerates strongly with time. These phenomena were interpreted by considering the effect of strong electric fields present during C-AFM experiments.
2009
D. Cavalcoli, M. Rossi., A. Tomasi, A.Cavallini (2009). Degeneracy and instability of nanocontacts between conductive tips and hydrogenated nanocrystalline Si surfaces in conductive atomic force microscopy. NANOTECHNOLOGY, 20, 045702-045708 [10.1088/0957-4484/20/4/045702].
D. Cavalcoli; M. Rossi.; A. Tomasi; A.Cavallini
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/67290
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 12
social impact