OBJECTIVE: We tested the hypothesis that subjects randomized to the 6 mL/kg predicted body weight tidal volume study group of the National Institutes of Health Acute Respiratory Distress Syndrome (ARDS) Network study had higher levels of intrinsic positive end-expiratory pressure (PEEP) than subjects randomized to the 12 mL/kg predicted body weight tidal volume study group. DESIGN: Secondary analysis of a subgroup from a randomized controlled trial. SETTING: Hospitals located in San Francisco, CA, and Seattle, WA. PATIENTS: Eighty-four patients enrolled in the ARDS Network tidal volume trial in San Francisco, CA, and Seattle, WA, with records of measurement of intrinsic PEEP. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Intrinsic PEEP was assessed a median of six times over the first 48 hrs of ARDS Network protocol ventilation in study subjects, with no significant difference in number of measurements between subjects randomized to the tidal volume protocol of 6 mL/kg compared with 12 mL/kg. We found that intrinsic PEEP was higher among subjects randomized to the 6 mL/kg protocol, with a median intrinsic PEEP of 1.3 cm H2O (interquartile range, 0-3.1 cm H2O), compared with a median intrinsic PEEP of 0.5 cm H2O (interquartile range, 0-1.5 cm H2O) among subjects randomized to 12 mL/kg (p = .029). There was no difference in total PEEP between the study groups. CONCLUSIONS: In a subgroup of ARDS Network subjects, intrinsic PEEP was statistically significantly higher in subjects randomized to the 6 mL/kg protocol than those in the 12 mL/kg study group. The amount of intrinsic PEEP was very low in both study groups, and difference of median intrinsic PEEP between the groups was <1 cm H2O. It is unlikely that the difference in intrinsic PEEP between the study groups was clinically important in the ARDS Network study of low tidal volume ventilation.

HOUGH CL, KALLET RH, RANIERI V, RUBENFELD GD, LUCE JM, HUDSON LD. (2005). Intrinsic positive end-expiratory pressure in Acute Respiratory Distress Syndrome (ARDS) Network subjects. CRITICAL CARE MEDICINE, 33(3), 527-532 [10.1097/01.ccm.0000155782.86244.42].

Intrinsic positive end-expiratory pressure in Acute Respiratory Distress Syndrome (ARDS) Network subjects

RANIERI V;
2005

Abstract

OBJECTIVE: We tested the hypothesis that subjects randomized to the 6 mL/kg predicted body weight tidal volume study group of the National Institutes of Health Acute Respiratory Distress Syndrome (ARDS) Network study had higher levels of intrinsic positive end-expiratory pressure (PEEP) than subjects randomized to the 12 mL/kg predicted body weight tidal volume study group. DESIGN: Secondary analysis of a subgroup from a randomized controlled trial. SETTING: Hospitals located in San Francisco, CA, and Seattle, WA. PATIENTS: Eighty-four patients enrolled in the ARDS Network tidal volume trial in San Francisco, CA, and Seattle, WA, with records of measurement of intrinsic PEEP. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Intrinsic PEEP was assessed a median of six times over the first 48 hrs of ARDS Network protocol ventilation in study subjects, with no significant difference in number of measurements between subjects randomized to the tidal volume protocol of 6 mL/kg compared with 12 mL/kg. We found that intrinsic PEEP was higher among subjects randomized to the 6 mL/kg protocol, with a median intrinsic PEEP of 1.3 cm H2O (interquartile range, 0-3.1 cm H2O), compared with a median intrinsic PEEP of 0.5 cm H2O (interquartile range, 0-1.5 cm H2O) among subjects randomized to 12 mL/kg (p = .029). There was no difference in total PEEP between the study groups. CONCLUSIONS: In a subgroup of ARDS Network subjects, intrinsic PEEP was statistically significantly higher in subjects randomized to the 6 mL/kg protocol than those in the 12 mL/kg study group. The amount of intrinsic PEEP was very low in both study groups, and difference of median intrinsic PEEP between the groups was <1 cm H2O. It is unlikely that the difference in intrinsic PEEP between the study groups was clinically important in the ARDS Network study of low tidal volume ventilation.
2005
HOUGH CL, KALLET RH, RANIERI V, RUBENFELD GD, LUCE JM, HUDSON LD. (2005). Intrinsic positive end-expiratory pressure in Acute Respiratory Distress Syndrome (ARDS) Network subjects. CRITICAL CARE MEDICINE, 33(3), 527-532 [10.1097/01.ccm.0000155782.86244.42].
HOUGH CL; KALLET RH; RANIERI V; RUBENFELD GD; LUCE JM; HUDSON LD.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/670445
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 23
social impact