Purpose Metaphyseal bone defects are a challenge in complex primary and revision total knee arthroplasty (TKA). Recently, several studies have been published with promising results about the use of Trabecular Metal (TM) cones to address bone defects. The aim of this study is to review the literature to assess the efficacy of TM cones to address metaphyseal bone loss. Methods A comprehensive search was performed on PubMed, Medline, CINAHL, Cochrane, Embase, and Google Scholar databases using various combinations of the following keywords: “metaphyseal,” “cones,” “tantalum,” “knee,” and “revision.” Only papers reporting clinical data about the use of trabecular metal cones were included in the analysis. In vitro studies, case reports, surgical technique, or other studies where it was not possible to collect clinical data were excluded. Patients characteristics, details of the surgical procedures, outcome, and complications were collected from each included study. Results No controlled studies were available in the literature and all the papers were case series. In 16 studies included, the records of 442 patients with 447 implants and 523 TM cones were reported. The mean follow-up was 42 months (range: 5–105) for 360 procedures. Among 437 procedures, 30.4% were septic revisions. The Anderson Orthopaedic Research Institute (AORI) classification was available for 352 defects: 13 type 1, 69 type 2A, 115 type 2B, and 155 type 3. To manage these 352 defects, 360 TM cones were implanted. Intraoperative fractures occurred 13 times (10 femoral/3 tibial), 6 required surgical fixation. The overall infection rate was 7.38%, and the infection rate for the aseptic procedures was 0.99%. An aseptic exchange was performed 13 times, among these procedures twoTM cones were loose. Signs of loosening were found just in 1.3% of the 523 TM cones implanted (5 femoral/2 tibial) during 447 procedures.

Are trabecular metal cones a valid option to treat metaphyseal bone defects in complex primary and revision knee arthroplasty?

Bonanzinga, Tommaso;Zaffagnini, Stefano;Marcacci, Maurilio;
2018

Abstract

Purpose Metaphyseal bone defects are a challenge in complex primary and revision total knee arthroplasty (TKA). Recently, several studies have been published with promising results about the use of Trabecular Metal (TM) cones to address bone defects. The aim of this study is to review the literature to assess the efficacy of TM cones to address metaphyseal bone loss. Methods A comprehensive search was performed on PubMed, Medline, CINAHL, Cochrane, Embase, and Google Scholar databases using various combinations of the following keywords: “metaphyseal,” “cones,” “tantalum,” “knee,” and “revision.” Only papers reporting clinical data about the use of trabecular metal cones were included in the analysis. In vitro studies, case reports, surgical technique, or other studies where it was not possible to collect clinical data were excluded. Patients characteristics, details of the surgical procedures, outcome, and complications were collected from each included study. Results No controlled studies were available in the literature and all the papers were case series. In 16 studies included, the records of 442 patients with 447 implants and 523 TM cones were reported. The mean follow-up was 42 months (range: 5–105) for 360 procedures. Among 437 procedures, 30.4% were septic revisions. The Anderson Orthopaedic Research Institute (AORI) classification was available for 352 defects: 13 type 1, 69 type 2A, 115 type 2B, and 155 type 3. To manage these 352 defects, 360 TM cones were implanted. Intraoperative fractures occurred 13 times (10 femoral/3 tibial), 6 required surgical fixation. The overall infection rate was 7.38%, and the infection rate for the aseptic procedures was 0.99%. An aseptic exchange was performed 13 times, among these procedures twoTM cones were loose. Signs of loosening were found just in 1.3% of the 523 TM cones implanted (5 femoral/2 tibial) during 447 procedures.
2018
Bonanzinga, Tommaso; Gehrke, Thorsten; Zahar, Akos; Zaffagnini, Stefano; Marcacci, Maurilio; Haasper, Carl
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/667521
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 32
  • ???jsp.display-item.citation.isi??? ND
social impact