PURPOSE: The majority of the techniques used to assess the primary implant stability are subjective and empirical and can be used during or after the surgery. The aim of this study is to evaluate the bone density prior to surgery, in order to give recommendations to the clinician about the best surgical technique and the type of implant which is needed. MATERIALS AND METHODS: A surgeon operated on 75 patients for 269 implants over the period 2010-2014. He required a CT to plan the surgery and he documented the type, the diameters, and the lengths of the implants, the insertion torque, and the ISQ values. At a later stage another clinician measured bone density and cortical thickness. We endeavoured to get the most accurate superimposition between the implants placed by the surgeon and those placed by the clinician. RESULTS: In maxilla ISQ showed a significant positive correlation with HU values detected for coronal-buccal (r = 0.302; p = 0.020) and middle-lingual (r = 0.295; p = 0.023). Torque showed a positive correlation with cortical bone thickness at the middle of the ridge (ρ = 0.196; p = 0.032). CONCLUSION: It is important to take into consideration the Hounsfield Units and the cortical thickness as predictive parameters during the preoperative assessment, with regard to the choice of the implant type as well as the surgical technique.

Clinical Relevance of Bone Density Values from CT Related to Dental Implant Stability: A Retrospective Study / Bruno, Vincenzo; Berti, Cesare*; Barausse, Carlo; Badino, Mauro; Gasparro, Roberta; Ippolito, Daniela Rita; Felice, Pietro. - In: BIOMED RESEARCH INTERNATIONAL. - ISSN 2314-6141. - ELETTRONICO. - 2018:Special Issue - New Biomaterials and Regenerative Medicine Strategies in Periodontology, Oral Surgery, Esthetic and Implant Dentistry 2018(2018), pp. 6758245.1-6758245.8. [10.1155/2018/6758245]

Clinical Relevance of Bone Density Values from CT Related to Dental Implant Stability: A Retrospective Study

Barausse, Carlo;Felice, Pietro
2018

Abstract

PURPOSE: The majority of the techniques used to assess the primary implant stability are subjective and empirical and can be used during or after the surgery. The aim of this study is to evaluate the bone density prior to surgery, in order to give recommendations to the clinician about the best surgical technique and the type of implant which is needed. MATERIALS AND METHODS: A surgeon operated on 75 patients for 269 implants over the period 2010-2014. He required a CT to plan the surgery and he documented the type, the diameters, and the lengths of the implants, the insertion torque, and the ISQ values. At a later stage another clinician measured bone density and cortical thickness. We endeavoured to get the most accurate superimposition between the implants placed by the surgeon and those placed by the clinician. RESULTS: In maxilla ISQ showed a significant positive correlation with HU values detected for coronal-buccal (r = 0.302; p = 0.020) and middle-lingual (r = 0.295; p = 0.023). Torque showed a positive correlation with cortical bone thickness at the middle of the ridge (ρ = 0.196; p = 0.032). CONCLUSION: It is important to take into consideration the Hounsfield Units and the cortical thickness as predictive parameters during the preoperative assessment, with regard to the choice of the implant type as well as the surgical technique.
2018
Clinical Relevance of Bone Density Values from CT Related to Dental Implant Stability: A Retrospective Study / Bruno, Vincenzo; Berti, Cesare*; Barausse, Carlo; Badino, Mauro; Gasparro, Roberta; Ippolito, Daniela Rita; Felice, Pietro. - In: BIOMED RESEARCH INTERNATIONAL. - ISSN 2314-6141. - ELETTRONICO. - 2018:Special Issue - New Biomaterials and Regenerative Medicine Strategies in Periodontology, Oral Surgery, Esthetic and Implant Dentistry 2018(2018), pp. 6758245.1-6758245.8. [10.1155/2018/6758245]
Bruno, Vincenzo; Berti, Cesare*; Barausse, Carlo; Badino, Mauro; Gasparro, Roberta; Ippolito, Daniela Rita; Felice, Pietro
File in questo prodotto:
File Dimensione Formato  
2018 - Bone density implant stability - Bruno_BRI.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 1.78 MB
Formato Adobe PDF
1.78 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/665422
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact