A 20 gas gaps multigap resistive plate chamber (MRPC) was built with thin (0.28 mm) glass sheets and 0.16 mm gas gap size. This chamber reaches 97% efficiency at 18.4 kV and a time resolution of 32 ps (sigma) at an instantaneous particle flux around 2.5 kHz/cm2. Compared to a 6 gaps MRPC with 0.22 mm gas gap, this 20-gap MRPC shows a higher rate capability and much better time resolution. The efficiencies of the 20-gap MRPC reach 95%, 93% and 88% at instantaneous fluxes of 10 kHz/cm2, 14.5 kHz/cm2 and 20 kHz/cm2, respectively. The efficiencies of the 6-gap MRPC at the same flux are 90%, 85% and 77%. The time resolution of 20-gap MRPC degrades with the increase of particle flux. However, a time resolution of 39 ps was obtained at an instantaneous flux of 10 kHz/cm2.

Liu, Z., Carnesecchi, F., Rodriguez, O., Williams, M., Zichichi, A., Zuyeuski, R. (2018). 20 gas gaps Multigap Resistive Plate Chamber: Improved rate capability with excellent time resolution. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 908, 383-387 [10.1016/j.nima.2018.08.096].

20 gas gaps Multigap Resistive Plate Chamber: Improved rate capability with excellent time resolution

Carnesecchi, F.;
2018

Abstract

A 20 gas gaps multigap resistive plate chamber (MRPC) was built with thin (0.28 mm) glass sheets and 0.16 mm gas gap size. This chamber reaches 97% efficiency at 18.4 kV and a time resolution of 32 ps (sigma) at an instantaneous particle flux around 2.5 kHz/cm2. Compared to a 6 gaps MRPC with 0.22 mm gas gap, this 20-gap MRPC shows a higher rate capability and much better time resolution. The efficiencies of the 20-gap MRPC reach 95%, 93% and 88% at instantaneous fluxes of 10 kHz/cm2, 14.5 kHz/cm2 and 20 kHz/cm2, respectively. The efficiencies of the 6-gap MRPC at the same flux are 90%, 85% and 77%. The time resolution of 20-gap MRPC degrades with the increase of particle flux. However, a time resolution of 39 ps was obtained at an instantaneous flux of 10 kHz/cm2.
2018
Liu, Z., Carnesecchi, F., Rodriguez, O., Williams, M., Zichichi, A., Zuyeuski, R. (2018). 20 gas gaps Multigap Resistive Plate Chamber: Improved rate capability with excellent time resolution. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 908, 383-387 [10.1016/j.nima.2018.08.096].
Liu, Z.; Carnesecchi, F.; Rodriguez, O.M.; Williams, M.C.S.; Zichichi, A.; Zuyeuski, R.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/664495
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact