This paper reports on the results of time resolution measurements of detectors consisting of SiPMs coupled to a scintillator. The R&D has been performed both in a cosmic-ray setup, at the Bologna INFN laboratories, and in a beam test, at the CERN T10 beam line. Different couplings, direct or by means of optical fibres, have been tested. The measurements indicate that to reach better time resolutions, it is important to have a direct coupling between the SiPM and the scintillator. A time resolution of 67 ps has been achieved, for the direct coupling, broadened by the full electronics chain jitter.

Time resolution measurements with SiPMs coupled to a scintillator / Alici, A.; Antonioli, P.; Arcelli, S.; Basile, M.; Bellini, F.; Carnesecchi, F.; Cavazza, D.; Cifarelli, L.; Cindolo, F.; Colocci, M.; Caro, A. De; Gruttola, D. De; Pasquale, S. De; Girard, M. Fusco; Hatzifotiadou, D.; Jacazio, N.; Liu, Z.; Rodriguez, O. Maragoto; Margotti, A.; Meninno, E.; Nania, R.; Noferini, F.; Pinazza, O.; Preghenella, R.; Scapparone, E.; Scioli, G.; Wilkinson, J.; Williams, M.C.S.; Zampolli, C.; Zichichi, A.; Zuyeuski, R.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - STAMPA. - 13:9(2018), pp. P09012.1-P09012.10. [10.1088/1748-0221/13/09/P09012]

Time resolution measurements with SiPMs coupled to a scintillator

Alici, A.;Arcelli, S.;Bellini, F.;Carnesecchi, F.;Cifarelli, L.;Colocci, M.;Jacazio, N.;Scioli, G.;
2018

Abstract

This paper reports on the results of time resolution measurements of detectors consisting of SiPMs coupled to a scintillator. The R&D has been performed both in a cosmic-ray setup, at the Bologna INFN laboratories, and in a beam test, at the CERN T10 beam line. Different couplings, direct or by means of optical fibres, have been tested. The measurements indicate that to reach better time resolutions, it is important to have a direct coupling between the SiPM and the scintillator. A time resolution of 67 ps has been achieved, for the direct coupling, broadened by the full electronics chain jitter.
2018
Time resolution measurements with SiPMs coupled to a scintillator / Alici, A.; Antonioli, P.; Arcelli, S.; Basile, M.; Bellini, F.; Carnesecchi, F.; Cavazza, D.; Cifarelli, L.; Cindolo, F.; Colocci, M.; Caro, A. De; Gruttola, D. De; Pasquale, S. De; Girard, M. Fusco; Hatzifotiadou, D.; Jacazio, N.; Liu, Z.; Rodriguez, O. Maragoto; Margotti, A.; Meninno, E.; Nania, R.; Noferini, F.; Pinazza, O.; Preghenella, R.; Scapparone, E.; Scioli, G.; Wilkinson, J.; Williams, M.C.S.; Zampolli, C.; Zichichi, A.; Zuyeuski, R.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - STAMPA. - 13:9(2018), pp. P09012.1-P09012.10. [10.1088/1748-0221/13/09/P09012]
Alici, A.; Antonioli, P.; Arcelli, S.; Basile, M.; Bellini, F.; Carnesecchi, F.; Cavazza, D.; Cifarelli, L.; Cindolo, F.; Colocci, M.; Caro, A. De; Gruttola, D. De; Pasquale, S. De; Girard, M. Fusco; Hatzifotiadou, D.; Jacazio, N.; Liu, Z.; Rodriguez, O. Maragoto; Margotti, A.; Meninno, E.; Nania, R.; Noferini, F.; Pinazza, O.; Preghenella, R.; Scapparone, E.; Scioli, G.; Wilkinson, J.; Williams, M.C.S.; Zampolli, C.; Zichichi, A.; Zuyeuski, R.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/664175
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact