This paper has the aim of providing possible solutions for PD measurements, noise rejection and PD source identification focusing mainly on extruded cables. PD tests performed on defective cables under DC and AC indicate how PD DC measurements can be done effectively, and show that noise rejection and PD source identification approaches used nowadays for AC might be extended with good potentiality also to DC.
Montanari, G.C., Seri, P., Cirioni, L. (2018). Measuring partial discharges in DC insulation systems. A challenge, but also a must. Institute of Electrical and Electronics Engineers Inc. [10.1109/ICPADM.2018.8401147].
Measuring partial discharges in DC insulation systems. A challenge, but also a must
Montanari, Gian Carlo;Seri, Paolo;CIRIONI, LEONARDO
2018
Abstract
This paper has the aim of providing possible solutions for PD measurements, noise rejection and PD source identification focusing mainly on extruded cables. PD tests performed on defective cables under DC and AC indicate how PD DC measurements can be done effectively, and show that noise rejection and PD source identification approaches used nowadays for AC might be extended with good potentiality also to DC.File in questo prodotto:
Eventuali allegati, non sono esposti
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.