Medium voltage (MV)/high voltage (HV) cable lines are high-value assets and require substantial costs for their installation or replacement. For this reason, the capability to assess the condition of cable lengths and accessories on site is of great importance. Cross-linked polyethylene (XLPE) insulation is extensively used for MV, HV, and extra-high voltage (EHV) class cables [1] thanks to its excellent voltage-endurance and thermomechanical properties. In particular, XLPE-insulated cables feature substantially lower losses, easier manufacturing and jointing procedures, better environmental compatibility, and higher operating temperature compared with impregnated paper cables, which lead to lower costs in procurement and operation [2], [3].

Wireless partial discharge tracking on cross-linked polyethylene MV and HV cables / Madonia, Antonino; Sanseverino, Eleonora Riva; Romano, Pietro; Troia, Ivan; Bononi, Stefano Franchi; Albertini, Marco; Giannini, Simone; Mazzanti, Giovanni. - In: IEEE ELECTRICAL INSULATION MAGAZINE. - ISSN 0883-7554. - STAMPA. - 34:6(2018), pp. 8507713.8-8507713.17. [10.1109/MEI.2018.8507713]

Wireless partial discharge tracking on cross-linked polyethylene MV and HV cables

Mazzanti, Giovanni
2018

Abstract

Medium voltage (MV)/high voltage (HV) cable lines are high-value assets and require substantial costs for their installation or replacement. For this reason, the capability to assess the condition of cable lengths and accessories on site is of great importance. Cross-linked polyethylene (XLPE) insulation is extensively used for MV, HV, and extra-high voltage (EHV) class cables [1] thanks to its excellent voltage-endurance and thermomechanical properties. In particular, XLPE-insulated cables feature substantially lower losses, easier manufacturing and jointing procedures, better environmental compatibility, and higher operating temperature compared with impregnated paper cables, which lead to lower costs in procurement and operation [2], [3].
2018
Wireless partial discharge tracking on cross-linked polyethylene MV and HV cables / Madonia, Antonino; Sanseverino, Eleonora Riva; Romano, Pietro; Troia, Ivan; Bononi, Stefano Franchi; Albertini, Marco; Giannini, Simone; Mazzanti, Giovanni. - In: IEEE ELECTRICAL INSULATION MAGAZINE. - ISSN 0883-7554. - STAMPA. - 34:6(2018), pp. 8507713.8-8507713.17. [10.1109/MEI.2018.8507713]
Madonia, Antonino; Sanseverino, Eleonora Riva; Romano, Pietro; Troia, Ivan; Bononi, Stefano Franchi; Albertini, Marco; Giannini, Simone; Mazzanti, Giovanni
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/650123
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 11
social impact