This paper presents a microfluidic push-pull probe for scanning electrochemical microscopy (SECM) consisting of a working microelectrode, an integrated counter/reference electrode and two microchannels for pushing and pulling an electrolyte solution to and away from a substrate. With such a configuration, a droplet of a permanently renewed redox mediator solution is maintained just at the probe tip to carry out SECM measurements on initially dry substrates or in microenvironments. For SECM imaging purposes, the probe fabricated in a soft polymer material is used in a contact regime. SECM images of various gold-on-glass samples demonstrate the proof-of-concept of a push-pull probe for local surface activity characterization with high spatial resolution even on vertically oriented substrates. Finite element computations were performed to guide the improvement of the probe sensitivity. © 2011 American Chemical Society.

Momotenko, D., Cortes-Salazar, F., Lesch, A., Wittstock, G., Girault, H.H. (2011). Microfluidic push-pull probe for scanning electrochemical microscopy. ANALYTICAL CHEMISTRY, 83(13), 5275-5282 [10.1021/ac2006729].

Microfluidic push-pull probe for scanning electrochemical microscopy

Lesch, Andreas;
2011

Abstract

This paper presents a microfluidic push-pull probe for scanning electrochemical microscopy (SECM) consisting of a working microelectrode, an integrated counter/reference electrode and two microchannels for pushing and pulling an electrolyte solution to and away from a substrate. With such a configuration, a droplet of a permanently renewed redox mediator solution is maintained just at the probe tip to carry out SECM measurements on initially dry substrates or in microenvironments. For SECM imaging purposes, the probe fabricated in a soft polymer material is used in a contact regime. SECM images of various gold-on-glass samples demonstrate the proof-of-concept of a push-pull probe for local surface activity characterization with high spatial resolution even on vertically oriented substrates. Finite element computations were performed to guide the improvement of the probe sensitivity. © 2011 American Chemical Society.
2011
Momotenko, D., Cortes-Salazar, F., Lesch, A., Wittstock, G., Girault, H.H. (2011). Microfluidic push-pull probe for scanning electrochemical microscopy. ANALYTICAL CHEMISTRY, 83(13), 5275-5282 [10.1021/ac2006729].
Momotenko, Dmitry; Cortes-Salazar, Fernando; Lesch, Andreas; Wittstock, Gunther; Girault, Hubert H.*
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/649806
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 49
social impact