This study aimed to assess the feasibility to plan and deliver highly heterogeneous doses to symptomatic large tumors using volumetric modulated arc therapy (VMAT) and simultaneous integrated boost (SIB) during a short course palliative accelerated radiotherapy.

Cilla S, D.F. (2018). Partially ablative radiotherapy (PAR) for large mass tumors using simultaneous integrated boost: A dose-escalation feasibility study. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 19(6), 35-43 [10.1002/acm2.12427].

Partially ablative radiotherapy (PAR) for large mass tumors using simultaneous integrated boost: A dose-escalation feasibility study

Buwenge M;Cammelli S;Zamagni A;Morganti AG.
2018

Abstract

This study aimed to assess the feasibility to plan and deliver highly heterogeneous doses to symptomatic large tumors using volumetric modulated arc therapy (VMAT) and simultaneous integrated boost (SIB) during a short course palliative accelerated radiotherapy.
2018
Cilla S, D.F. (2018). Partially ablative radiotherapy (PAR) for large mass tumors using simultaneous integrated boost: A dose-escalation feasibility study. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 19(6), 35-43 [10.1002/acm2.12427].
Cilla S, Deodato F, Ianiro A, Macchia G, Picardi V, Buwenge M, Cammelli S, Zamagni A, Valentini V, Morganti AG.
File in questo prodotto:
File Dimensione Formato  
Cilla_et_al-2018-Journal_of_Applied_Clinical_Medical_Physics.pdf

accesso aperto

Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 869.07 kB
Formato Adobe PDF
869.07 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/645229
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact