Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
CRIS Current Research Information System
Amplitude models are constructed to describe the resonance structure of D0 → K− π+ π+ π− and D0 → K+ π− π− π+ decays using pp collision data collected at centre-of-mass energies of 7 and 8 TeV with the LHCb experiment, corresponding to an integrated luminosity of 3.0 fb^−1. The largest contributions to both decay amplitudes are found to come from axial resonances, with decay modes D0 → a1(1260)+ K− and D0 → K1(1270/1400)+ π− being prominent in D0 → K− π+ π+ π− and D0 → K+ π− π− π+, respectively. Precise measurements of the lineshape parameters and couplings of the a1(1260)+, K1(1270)− and K(1460)− resonances are made, and a quasi model-independent study of the K(1460)− resonance is performed. The coherence factor of the decays is calculated from the amplitude models to be R_K3π = 0.459 ± 0.010(stat) ± 0.012(syst) ± 0.020(model), which is consistent with direct measurements. These models will be useful in future measurements of the unitary-triangle angle γ and studies of charm mixing and CP violation.
Aaij, R., Adeva, B., Adinolfi, M., Ajaltouni, Z., Akar, S., Albrecht, J., et al. (2018). Studies of the Resonance Structure in D0 → K∓ π± π± π∓ Decays. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 78(6), 1-31 [10.1140/epjc/s10052-018-5758-4].
Studies of the Resonance Structure in D0 → K∓ π± π± π∓ Decays
Amplitude models are constructed to describe the resonance structure of D0 → K− π+ π+ π− and D0 → K+ π− π− π+ decays using pp collision data collected at centre-of-mass energies of 7 and 8 TeV with the LHCb experiment, corresponding to an integrated luminosity of 3.0 fb^−1. The largest contributions to both decay amplitudes are found to come from axial resonances, with decay modes D0 → a1(1260)+ K− and D0 → K1(1270/1400)+ π− being prominent in D0 → K− π+ π+ π− and D0 → K+ π− π− π+, respectively. Precise measurements of the lineshape parameters and couplings of the a1(1260)+, K1(1270)− and K(1460)− resonances are made, and a quasi model-independent study of the K(1460)− resonance is performed. The coherence factor of the decays is calculated from the amplitude models to be R_K3π = 0.459 ± 0.010(stat) ± 0.012(syst) ± 0.020(model), which is consistent with direct measurements. These models will be useful in future measurements of the unitary-triangle angle γ and studies of charm mixing and CP violation.
Aaij, R., Adeva, B., Adinolfi, M., Ajaltouni, Z., Akar, S., Albrecht, J., et al. (2018). Studies of the Resonance Structure in D0 → K∓ π± π± π∓ Decays. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 78(6), 1-31 [10.1140/epjc/s10052-018-5758-4].
Aaij, R.; Adeva, B.; Adinolfi, M.; Ajaltouni, Z.; Akar, S.; Albrecht, J.; Alessio, F.; Alexander, M.; Alfonso Albero, A.; Ali, S.; Alkhazov, G.; Alvar...espandi
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/640552
Citazioni
ND
31
22
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.