OBJECTIVE: To evaluate diagnostic accuracy of quantitative fetal fibronectin (qfFN) test in predicting preterm birth (PTB) risk <34 weeks' gestation or within 14 days from testing. We explored the predictive potential of the test in five-predefined PTB risk categories based on predefined qfFN thresholds (<10, 10-49, 50-199, 200-499 and ≥500 ng/mL). METHODS: Measurement of cervicovaginal qfFN with Rapid fFN 10Q System (Hologic) in 126 women with singleton pregnancy (23-33 weeks' gestation) reporting signs and symptoms indicative of preterm labour (PTL). RESULTS: For PTB prediction risk <34 weeks' gestation, sensitivity decreased from 100% to 41.7% and specificity increased from 0% to 99.1% with increasing fFN thresholds. Positive predictive value (PPV) increased from 9.5% to 83.3% with increasing qfFN thresholds, while negative predictive value (NPV) was higher than 90% among the fFN-predefined categories. Diagnostic accuracy results showed an area under a receiving operator characteristic (ROC) curve of 84.5% (95% CI, 0.770-0.903). For delivery prediction within 14 days from the testing, sensitivity decreased from 100% to 42.8% and specificity increased from 0% to 100% with increasing fFN thresholds. Diagnostic accuracy determined by the ROC curve was 66.1% (95% CI, 0.330-0.902). CONCLUSIONS: The QfFN thresholds of tests are a useful tool to distinguish pregnant women for PTB prediction risk <34 weeks' gestation.

Evaluation of quantitative fFn test in predicting the risk of preterm birth.

ALFONSI, LUCILLA;BINI, VALENTINA;COZZOLINO, MARIANNA;Facchinetti F;Ferrari F;Todros T;Rizzo N
Methodology
;
Bisulli M;
2017

Abstract

OBJECTIVE: To evaluate diagnostic accuracy of quantitative fetal fibronectin (qfFN) test in predicting preterm birth (PTB) risk <34 weeks' gestation or within 14 days from testing. We explored the predictive potential of the test in five-predefined PTB risk categories based on predefined qfFN thresholds (<10, 10-49, 50-199, 200-499 and ≥500 ng/mL). METHODS: Measurement of cervicovaginal qfFN with Rapid fFN 10Q System (Hologic) in 126 women with singleton pregnancy (23-33 weeks' gestation) reporting signs and symptoms indicative of preterm labour (PTL). RESULTS: For PTB prediction risk <34 weeks' gestation, sensitivity decreased from 100% to 41.7% and specificity increased from 0% to 99.1% with increasing fFN thresholds. Positive predictive value (PPV) increased from 9.5% to 83.3% with increasing qfFN thresholds, while negative predictive value (NPV) was higher than 90% among the fFN-predefined categories. Diagnostic accuracy results showed an area under a receiving operator characteristic (ROC) curve of 84.5% (95% CI, 0.770-0.903). For delivery prediction within 14 days from the testing, sensitivity decreased from 100% to 42.8% and specificity increased from 0% to 100% with increasing fFN thresholds. Diagnostic accuracy determined by the ROC curve was 66.1% (95% CI, 0.330-0.902). CONCLUSIONS: The QfFN thresholds of tests are a useful tool to distinguish pregnant women for PTB prediction risk <34 weeks' gestation.
2017
Centra M, Coata G, Picchiassi E, Alfonsi L, Meniconi S, Bini V, Di Tommaso MR, Cozzolino M, Facchinetti F, Ferrari F, Gervasi MT, Rusconi S, Todros T, Frisina V, Rizzo N, Bisulli M, Di Renzo GC.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/628012
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 9
social impact