A compact readout based on Silicon PhotoMultipliers can provide longitudinal segmentation to shashlik calorimeters. Direct fiber-photosensor coupling prevents the fiber bundling and the ultra-compactness of new generation SiPMs allows to embed the readout in the bulk of the calorimeter. Possible applications for this detector are high granularity devices for collider physics, beam dump experiments and nonconventional neutrino facilities. In July 2016 the SCENTT collaboration tested a prototype for an electromagnetic calorimeter sampled every ~4 X0 at the CERN PS-T9 beamline. The results for the linearity and energy resolution are provided.

Longitudinally segmented shashlik calorimeters with SiPM readout: The SCENTT experiment / Berra, A.; Bnzzolan, C.; Cecchini, S.; Cindolo, F.; Jollet, C.; Longhin, A.; Ludovici, L.; Mandrioli, G.; Mascagna, V.; Mauri, N.; Meregaglia, A.; Paoloni, A.; Pasqualini, L.; Patrizii, L.; Pozzato, M.; Pupilli, F.; Prest, M.; Sirri, G.; Terranova, F.; Vallazza, E.; Votano, L.. - STAMPA. - 2017-:(2016), pp. 8069860.1-8069860.3. (Intervento presentato al convegno 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 tenutosi a fra nel 2016) [10.1109/NSSMIC.2016.8069860].

Longitudinally segmented shashlik calorimeters with SiPM readout: The SCENTT experiment

LONGHIN, ANDREA;Mauri, N.;Pasqualini, L.;Patrizii, L.;Pozzato, M.;Sirri, G.;
2016

Abstract

A compact readout based on Silicon PhotoMultipliers can provide longitudinal segmentation to shashlik calorimeters. Direct fiber-photosensor coupling prevents the fiber bundling and the ultra-compactness of new generation SiPMs allows to embed the readout in the bulk of the calorimeter. Possible applications for this detector are high granularity devices for collider physics, beam dump experiments and nonconventional neutrino facilities. In July 2016 the SCENTT collaboration tested a prototype for an electromagnetic calorimeter sampled every ~4 X0 at the CERN PS-T9 beamline. The results for the linearity and energy resolution are provided.
2016
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
1
3
Longitudinally segmented shashlik calorimeters with SiPM readout: The SCENTT experiment / Berra, A.; Bnzzolan, C.; Cecchini, S.; Cindolo, F.; Jollet, C.; Longhin, A.; Ludovici, L.; Mandrioli, G.; Mascagna, V.; Mauri, N.; Meregaglia, A.; Paoloni, A.; Pasqualini, L.; Patrizii, L.; Pozzato, M.; Pupilli, F.; Prest, M.; Sirri, G.; Terranova, F.; Vallazza, E.; Votano, L.. - STAMPA. - 2017-:(2016), pp. 8069860.1-8069860.3. (Intervento presentato al convegno 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 tenutosi a fra nel 2016) [10.1109/NSSMIC.2016.8069860].
Berra, A.; Bnzzolan, C.; Cecchini, S.; Cindolo, F.; Jollet, C.; Longhin, A.; Ludovici, L.; Mandrioli, G.; Mascagna, V.; Mauri, N.; Meregaglia, A.; Paoloni, A.; Pasqualini, L.; Patrizii, L.; Pozzato, M.; Pupilli, F.; Prest, M.; Sirri, G.; Terranova, F.; Vallazza, E.; Votano, L.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/627118
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact