Cling films are prepared by adding (5–30% w/w) adipates, citrates, and phthalates. The adverse effects on human health of the plasticizers have been demonstrated, and then their content in food contact plastics and possible migration to foodstuffs must be carefully checked. To offer an easier tool to perform these controls, a Soxhlet extraction by ethyl acetate and a multi residue chromatography analysis, with Flame Ionization Detector, have been optimised for the application in evaluating both the real content of plasticizers in films and freezing bags, and their migrated amounts in simulants. The average extraction yield was 95±10%. The chromatographic analysis was able to determine 16 different compounds, clearly separated, taking only 25 min to complete the assay. The detection limits ranged from 0.07 to 0.7% (w/w). The total amount of plasticizers in the packaging products was comprised between 3 and 10% (w/w). Extracted and migrated amounts were compared, and they resulted in good agreement. No migration of Phthalates, whose presence has been demonstrated in some samples, has been observed. It has been also demonstrated that a prolonged contact (till 60 days) did not increase the amount of migrated plasticizers, and then the risks for health.

Extraction and gas chromatographic evaluation of plasticizers content in food packaging film / M. Bonini; E.E rrani; G. Zerbinati; E. Ferri; S. Girotti.. - In: MICROCHEMICAL JOURNAL. - ISSN 0026-265X. - STAMPA. - 90:(2008), pp. 31-36. [10.1016/j.microc.2008.03.002]

Extraction and gas chromatographic evaluation of plasticizers content in food packaging film

FERRI, ELIDA NORA;GIROTTI, STEFANO
2008

Abstract

Cling films are prepared by adding (5–30% w/w) adipates, citrates, and phthalates. The adverse effects on human health of the plasticizers have been demonstrated, and then their content in food contact plastics and possible migration to foodstuffs must be carefully checked. To offer an easier tool to perform these controls, a Soxhlet extraction by ethyl acetate and a multi residue chromatography analysis, with Flame Ionization Detector, have been optimised for the application in evaluating both the real content of plasticizers in films and freezing bags, and their migrated amounts in simulants. The average extraction yield was 95±10%. The chromatographic analysis was able to determine 16 different compounds, clearly separated, taking only 25 min to complete the assay. The detection limits ranged from 0.07 to 0.7% (w/w). The total amount of plasticizers in the packaging products was comprised between 3 and 10% (w/w). Extracted and migrated amounts were compared, and they resulted in good agreement. No migration of Phthalates, whose presence has been demonstrated in some samples, has been observed. It has been also demonstrated that a prolonged contact (till 60 days) did not increase the amount of migrated plasticizers, and then the risks for health.
2008
Extraction and gas chromatographic evaluation of plasticizers content in food packaging film / M. Bonini; E.E rrani; G. Zerbinati; E. Ferri; S. Girotti.. - In: MICROCHEMICAL JOURNAL. - ISSN 0026-265X. - STAMPA. - 90:(2008), pp. 31-36. [10.1016/j.microc.2008.03.002]
M. Bonini; E.E rrani; G. Zerbinati; E. Ferri; S. Girotti.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/62649
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 64
  • ???jsp.display-item.citation.isi??? 59
social impact