Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
CRIS Current Research Information System
The33S(n,α)30Si cross section measurement, using10B(n,α) as reference, at the n-TOF Experimental Area 2 (EAR2) facility at CERN is presented. Data from 0.01 eV to 100 keV are provided and, for the first time, the cross section is measured in the range from 0.01 eV to 10 keV. These data may be used for a future evaluation of the cross section because present evaluations exhibit large discrepancies. The33S(n,α)30Si reaction is of interest in medical physics because of its possible use as a cooperative target to boron in Neutron Capture Therapy (NCT).
The33S(n,α)30Si cross section measurement at n-TOF-EAR2 (CERN): From 0.01 eV to the resonance region
Sabaté-Gilarte, M.;Praena, J.;Porras, I.;Quesada, J. M.;Aberle, O.;Andrzejewski, J.;Audouin, L.;Bécares, V.;Bacak, M.;Balibrea-Correa, J.;Barbagallo, M.;Barros, S.;Bečvář, F.;Beinrucker, C.;Berthoumieux, E.;Billowes, J.;Bosnar, D.;Brugger, M.;Camaño, M.;Calviño, F.;Calviani, M.;Cano-Ott, D.;Cardella, R.;Casanovas, A.;Castelluccio, D. M.;Cerutti, F.;Chen, Y. H.;Chiaveri, E.;Colonna, N.;Cortés, G.;Cortés-Giraldo, M. A.;Cosentino, L.;Damone, L. A.;Diakaki, M.;Domingo-Pardo, C.;Dressler, R.;Dupont, E.;Durán, I.;Fernández-Domínguez, B.;Ferrari, A.;Ferreira, P.;Finocchiaro, P.;Furman, V.;Gödel, K.;García-Rios, A.;Gawlik, A.;Glodariu, T.;Gonçalves, I. F.;González, E.;Goverdovski, A.;Griesmayer, E.;Guerrero, C.;Gunsing, F.;Harada, H.;Heftrich, T.;Heinitz, S.;Heyse, J.;Jenkins, D. G.;Jericha, E.;Käppeler, F.;Kadi, Y.;Katabuchi, T.;Kavrigin, P.;Ketlerov, V.;Khryachkov, V.;Kimura, A.;Kivel, N.;Kokkoris, M.;Krtička, M.;Leal-Cidoncha, E.;Lederer, C.;Leeb, H.;Lerendegui-Marco, J.;Meo, S. Lo;Lonsdale, S. J.;Losito, R.;Macina, D.;Marganiec, J.;Martínez, T.;Massimi, C.;Mastinu, P.;Mastromarco, M.;Matteucci, F.;Maugeri, E. A.;Mendoza, E.;Mengoni, A.;Milazzo, P. M.;Mingrone, F.;Mirea, M.;Montesano, S.;Musumarra, A.;Nolte, R.;Oprea, A.;Patronis, N.;Pavlik, A.;Perkowski, J.;Rajeev, K.;Rauscher, T.;Reifarth, R.;Riego-Perez, A.;Rout, P.;Rubbia, C.;Ryan, J. A.;Saxena, A.;Schillebeeckx, P.;Schmidt, S.;Schumann, D.;Sedyshev, P.;Smith, A. G.;Stamatopoulos, A.;Tagliente, G.;Tain, J. L.;Tarifeño-Saldivia, A.;Tassan-Got, L.;Tsinganis, A.;Valenta, S.;Vannini, G.;Variale, V.;Vaz, P.;Ventura, A.;Vlachoudis, V.;Vlastou, R.;Wallner, A.;Warren, S.;Weigand, M.;Weiss, C.;Wolf, C.;Woods, P. J.;Wright, T.;Ž Ugec, P.
2017
Abstract
The33S(n,α)30Si cross section measurement, using10B(n,α) as reference, at the n-TOF Experimental Area 2 (EAR2) facility at CERN is presented. Data from 0.01 eV to 100 keV are provided and, for the first time, the cross section is measured in the range from 0.01 eV to 10 keV. These data may be used for a future evaluation of the cross section because present evaluations exhibit large discrepancies. The33S(n,α)30Si reaction is of interest in medical physics because of its possible use as a cooperative target to boron in Neutron Capture Therapy (NCT).
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/625336
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
3
3
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.