City breathability refers to the air exchange process between the flows above and within urban canopy layers (UCL) and that of in-canopy flow, measuring the potential of wind to remove and dilute pollutants, heat and other scalars in a city. Bulk flow parameters such as in-canopy velocity (Uc) and exchange velocity (UE) have been applied to evaluate the city breathability. Both wind tunnel experiments and computational fluid dynamics (CFD) simulations were used to study the flow adjustment and the variation of city breathability through urban-like models with different building packing densities. We experimentally studied some 25-row and 15-column aligned cubic building arrays (the building width B=72 mm and building heights H=B) in a closed-circuit boundary layer wind tunnel. Effect of building packing densities (λp=λf=0.11, 0.25, 0.44) on flow adjustment and drag force of each buildings were measured. Wind tunnel data show that wind speed decreases quickly through building arrays due to strong building drag. The first upstream building induces the strongest flow resistance. The flow adjustment length varies slightly with building packing densities. Larger building packing density produces lower drag force by individual buildings and attains smaller velocity in urban canopy layers, which causes weaker city breathability capacity. In CFD simulations, we performed seven test cases with various building packing densities of λp=λf=0.0625, 0.11, 0.25, 0.36, 0.44 and 0.56. In the cases of λp=λf=0.11, 0.25, 0.44, the simulated profiles of velocity and drag force agree with experiment data well. We computed Uc and UE, which represent horizontal and vertical ventilation capacity respectively. The inlet velocity at 2.5 times building height in the upstream free flow is defined as the reference velocity Uref. Results show that UE/Uref changes slightly (1.1% to 0.7%) but Uc/Uref significantly decreases from 0.4 to 0.1 as building packing densities rise from 0.0625 to 0.56. Although UE is induced by both mean flows and turbulent momentum flux across the top surface of urban canopy, vertical turbulent diffusion is found to contribute mostly to UE.

The Influence of Building Packing Densities on Flow Adjustment and City Breathability in Urban-like Geometries / Chen L., Hang J., Sandberg M., Claesson L., Di Sabatino S.. - In: PROCEDIA ENGINEERING. - ISSN 1877-7058. - STAMPA. - 198:(2017), pp. 758-769. [10.1016/j.proeng.2017.07.127]

The Influence of Building Packing Densities on Flow Adjustment and City Breathability in Urban-like Geometries

Di Sabatino S.
2017

Abstract

City breathability refers to the air exchange process between the flows above and within urban canopy layers (UCL) and that of in-canopy flow, measuring the potential of wind to remove and dilute pollutants, heat and other scalars in a city. Bulk flow parameters such as in-canopy velocity (Uc) and exchange velocity (UE) have been applied to evaluate the city breathability. Both wind tunnel experiments and computational fluid dynamics (CFD) simulations were used to study the flow adjustment and the variation of city breathability through urban-like models with different building packing densities. We experimentally studied some 25-row and 15-column aligned cubic building arrays (the building width B=72 mm and building heights H=B) in a closed-circuit boundary layer wind tunnel. Effect of building packing densities (λp=λf=0.11, 0.25, 0.44) on flow adjustment and drag force of each buildings were measured. Wind tunnel data show that wind speed decreases quickly through building arrays due to strong building drag. The first upstream building induces the strongest flow resistance. The flow adjustment length varies slightly with building packing densities. Larger building packing density produces lower drag force by individual buildings and attains smaller velocity in urban canopy layers, which causes weaker city breathability capacity. In CFD simulations, we performed seven test cases with various building packing densities of λp=λf=0.0625, 0.11, 0.25, 0.36, 0.44 and 0.56. In the cases of λp=λf=0.11, 0.25, 0.44, the simulated profiles of velocity and drag force agree with experiment data well. We computed Uc and UE, which represent horizontal and vertical ventilation capacity respectively. The inlet velocity at 2.5 times building height in the upstream free flow is defined as the reference velocity Uref. Results show that UE/Uref changes slightly (1.1% to 0.7%) but Uc/Uref significantly decreases from 0.4 to 0.1 as building packing densities rise from 0.0625 to 0.56. Although UE is induced by both mean flows and turbulent momentum flux across the top surface of urban canopy, vertical turbulent diffusion is found to contribute mostly to UE.
2017
The Influence of Building Packing Densities on Flow Adjustment and City Breathability in Urban-like Geometries / Chen L., Hang J., Sandberg M., Claesson L., Di Sabatino S.. - In: PROCEDIA ENGINEERING. - ISSN 1877-7058. - STAMPA. - 198:(2017), pp. 758-769. [10.1016/j.proeng.2017.07.127]
Chen L., Hang J., Sandberg M., Claesson L., Di Sabatino S.
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/624677
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact