Background: DES has reduced rates of restenosis compared with BMS but it has been associated with delayed healing and increase of stent thrombosis. The aim of our study was to evaluate the vascular time-related changes following implantation of a new SES coated with an amorphous silicon carbide that allows faster re-endothelisation (Orsiro-Biotronik). Methods: This prospective registry enrolled STEMI-patients with multi-vessel disease, thus candidates for a two-step procedure. PCI of the culprit lesion was performed with at least one Orsiro stent that was OCT-analysed during the second-step procedure (deferred to 30,90 and 180-days). Results: 16 of the 95 patients with MVD underwent an OCT evaluation of the study device implanted in the culprit lesion during the second-step staged procedure and were enrolled in the present Registry. A total of 3060-struts were analysed. The percentage of uncovered struts was 19.6% at30-days, 1.3% at90-days and 1.8% at180-days (p < 0.001). The percentage of cross section with ⥠1 uncovered struts were 51.3% at30-days, 6.5% at90-days and 5.7% at180-days (p < 0.001). The percentage of cross sections containing thrombus was 6.2% at30-days while no thrombus was detected both at90 and 180-days. Conclusions: Our data shows that the new Orsiro stent promotes early and persistent strut coverage with low peri-strut thrombus. This pilot OCT evaluation might suggest a low incidence of late adverse events and anticipate safe outcome after early withdrawal of dual antiplatelet therapy.
Secco, G.G., Mattesini, A., Fattori, R., Parisi, R., Castriota, F., Vercellino, M., et al. (2016). Time-related changes in neointimal tissue coverage of a novel Sirolimus eluting stent: Serial observations with optical coherence tomography. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 17(1), 38-43 [10.1016/j.carrev.2015.12.001].
Time-related changes in neointimal tissue coverage of a novel Sirolimus eluting stent: Serial observations with optical coherence tomography
Fattori, Rossella;Castriota, Fausto;Dall'Ara, Gianni;
2016
Abstract
Background: DES has reduced rates of restenosis compared with BMS but it has been associated with delayed healing and increase of stent thrombosis. The aim of our study was to evaluate the vascular time-related changes following implantation of a new SES coated with an amorphous silicon carbide that allows faster re-endothelisation (Orsiro-Biotronik). Methods: This prospective registry enrolled STEMI-patients with multi-vessel disease, thus candidates for a two-step procedure. PCI of the culprit lesion was performed with at least one Orsiro stent that was OCT-analysed during the second-step procedure (deferred to 30,90 and 180-days). Results: 16 of the 95 patients with MVD underwent an OCT evaluation of the study device implanted in the culprit lesion during the second-step staged procedure and were enrolled in the present Registry. A total of 3060-struts were analysed. The percentage of uncovered struts was 19.6% at30-days, 1.3% at90-days and 1.8% at180-days (p < 0.001). The percentage of cross section with ⥠1 uncovered struts were 51.3% at30-days, 6.5% at90-days and 5.7% at180-days (p < 0.001). The percentage of cross sections containing thrombus was 6.2% at30-days while no thrombus was detected both at90 and 180-days. Conclusions: Our data shows that the new Orsiro stent promotes early and persistent strut coverage with low peri-strut thrombus. This pilot OCT evaluation might suggest a low incidence of late adverse events and anticipate safe outcome after early withdrawal of dual antiplatelet therapy.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.