Extensive mitral annulus calcifications are considered a contraindication for valve surgery. We describe the case of a 76-year-old female with severe mitral and aortic stenosis associated with extensive calcifications of the heart. The patient underwent an open mitroaortic valve replacement using transcatheter aortic valve implantation with an Edwards SAPIEN XT valve (Edwards Lifesciences Corp., Irvine, CA, USA) in the mitral position. T he a ortic valve was replaced u sing a s tentless v alve p rosthesis (LivaNova S OLO; L ivaNova PLC, London, UK). Postoperative echocardiography showed that the prosthetic valve was in the correct position and there were no paravalvular leaks. A bailout open transcatheter valve implantation can be considered a safe and effective option in selected cases with an extensively calcified mitral valve.
Alfonsi, J., Murana, G., Corsini, A., Savini, C., Roberto Di, B., Pacini, D. (2017). Transcatheter mitral valve implantation in open heart surgery: An off-label technique. THE KOREAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 50(6), 467-470 [10.5090/kjtcs.2017.50.6.467].
Transcatheter mitral valve implantation in open heart surgery: An off-label technique
Alfonsi, Jacopo;Murana, Giacomo;Corsini, Anna;Savini, Carlo;Bartolomeo, Roberto Di;Pacini, Davide
2017
Abstract
Extensive mitral annulus calcifications are considered a contraindication for valve surgery. We describe the case of a 76-year-old female with severe mitral and aortic stenosis associated with extensive calcifications of the heart. The patient underwent an open mitroaortic valve replacement using transcatheter aortic valve implantation with an Edwards SAPIEN XT valve (Edwards Lifesciences Corp., Irvine, CA, USA) in the mitral position. T he a ortic valve was replaced u sing a s tentless v alve p rosthesis (LivaNova S OLO; L ivaNova PLC, London, UK). Postoperative echocardiography showed that the prosthetic valve was in the correct position and there were no paravalvular leaks. A bailout open transcatheter valve implantation can be considered a safe and effective option in selected cases with an extensively calcified mitral valve.File | Dimensione | Formato | |
---|---|---|---|
kjtcv-50-467.pdf
accesso aperto
Tipo:
Versione (PDF) editoriale
Licenza:
Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale (CCBYNC)
Dimensione
3.84 MB
Formato
Adobe PDF
|
3.84 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.