There is a lack of consensus on how endoscopic ultrasound (EUS)-guided pseudocyst drainage and endoscopic necrosectomy should be performed. This survey was carried out amongst members of the EUS Journal Editorial Board to describe their practices in performing this procedure. This was a worldwide multi-institutional survey amongst members of the EUS Journal Editorial Board in May 2017. The responses to a 22-question survey with respect to the practice of EUS-guided pseudocyst drainage and endoscopic necrosectomy were obtained. Twenty-two endoscopists responded to the questionnaire as follows: 72.7% (16/22) were of the opinion that lumen-apposing metal stents (LAMS) should be the standard of care for the creation of an endoscopic cystenterostomy in patients with pancreatic walled-offnecrosis (WON); 95.5% (21/22) recommended large diameter (d=15 mm) LAMS for drainage in patients with WON; 54.5% (12/22) would not dilate LAMS after placement into the WOPN; 86.4% (19/22) would not perform endoscopic necrosectomy during the same procedure as the creation of the cystenterostomy; 45.5% (10/22) recommend that agents, such as diluted hydrogen peroxide, should be used to lavage the peripancreatic fluid collection (PFC) cavity in patients with WON; and 45.5% (10/22) considered a naso-cystic or other tube to be necessary for lavage of WON after initial drainage. The mean optimal interval recommended for endoscopic necrosectomy procedures after EUS-guided drainage was 6.23 days. The mean optimal interval recommended for repeat imaging in patients undergoing endoscopic necrosectomy was 12.32 days. The mean time recommended for LAMS removal was 4.59 weeks. This is the first worldwide survey on the practice of EUS-guided pseudocyst drainage and endoscopic necrosectomy. There were wide variations in practice and randomized studies are urgently needed to establish the best approach for management of this condition. There is also a pressing need to establish a best practice consensus.

A multi-institutional consensus on how to perform endoscopic ultrasound-guided peri-pancreatic fluid collection drainage and endoscopic necrosectomy

FUSAROLI, PIETRO;
2017

Abstract

There is a lack of consensus on how endoscopic ultrasound (EUS)-guided pseudocyst drainage and endoscopic necrosectomy should be performed. This survey was carried out amongst members of the EUS Journal Editorial Board to describe their practices in performing this procedure. This was a worldwide multi-institutional survey amongst members of the EUS Journal Editorial Board in May 2017. The responses to a 22-question survey with respect to the practice of EUS-guided pseudocyst drainage and endoscopic necrosectomy were obtained. Twenty-two endoscopists responded to the questionnaire as follows: 72.7% (16/22) were of the opinion that lumen-apposing metal stents (LAMS) should be the standard of care for the creation of an endoscopic cystenterostomy in patients with pancreatic walled-offnecrosis (WON); 95.5% (21/22) recommended large diameter (d=15 mm) LAMS for drainage in patients with WON; 54.5% (12/22) would not dilate LAMS after placement into the WOPN; 86.4% (19/22) would not perform endoscopic necrosectomy during the same procedure as the creation of the cystenterostomy; 45.5% (10/22) recommend that agents, such as diluted hydrogen peroxide, should be used to lavage the peripancreatic fluid collection (PFC) cavity in patients with WON; and 45.5% (10/22) considered a naso-cystic or other tube to be necessary for lavage of WON after initial drainage. The mean optimal interval recommended for endoscopic necrosectomy procedures after EUS-guided drainage was 6.23 days. The mean optimal interval recommended for repeat imaging in patients undergoing endoscopic necrosectomy was 12.32 days. The mean time recommended for LAMS removal was 4.59 weeks. This is the first worldwide survey on the practice of EUS-guided pseudocyst drainage and endoscopic necrosectomy. There were wide variations in practice and randomized studies are urgently needed to establish the best approach for management of this condition. There is also a pressing need to establish a best practice consensus.
2017
Guo, Jintao; Saftoiu, Adrian; Vilmann, Peter; Fusaroli, Pietro; Giovannini, Marc; Mishra, Girish; Rana, Surinder S.; Ho, Sammy; Poley, Jan-werner; Ang, Tiing Leong; Kalaitzakis, Evangelos; Siddiqui, Ali A.; De La Mora-levy, Jose G.; Lakhtakia, Sundeep; Bhutani, Manoop S.; Sharma, Malay; Mukai, Shuntaro; Garg, Pramod Kumar; Lee, Linda S.; Vila, Juan J.; Artifon, Everson; Adler, Douglas G.; Sun, Siyu
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/610043
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 25
  • Scopus 69
  • ???jsp.display-item.citation.isi??? 66
social impact