Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
CRIS Current Research Information System
We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A blind analysis was applied to the last run recorded between April 2013 and January 2014 prior to combining the results. The ultralow electromagnetic background of the experiment, ∼5 × 10−3 events=ðkeVee× kg × dayÞ) before electronic recoil rejection, together with the increased exposure of 48 kg × yr, improves the sensitivity. A profile likelihood analysis using an energy range of ð6.6–43.3Þ keVnr sets a limit on the elastic, spin-independent WIMP-nucleon scattering cross section for WIMP masses above 8 GeV=c2, with a minimum of 1.1×10−45 cm2 at 50GeV=c2 and 90%confidence level.We also report updated constraints on the elastic, spin-dependent WIMP-nucleon cross sections obtained with the same data. We set upper limits on the WIMP-neutron (proton) cross section with a minimum of 2.0 × 10−40 cm2 (52 × 10−40 cm2) at a WIMP mass of 50 GeV=c2, at 90% confidence level.
XENON100 dark matter results from a combination of 477 live days / Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. d.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. l.; Berger, T.; Breur, P. a.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. m. r.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. p.; Conrad, J.; Cussonneau, J. p.; Decowski, M. p.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Duchovni, E.; Fei, J.; Ferella, A. d.; Fieguth, A.; Franco, D.; Fulgione, W.; Gallo Rosso, A.; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Goetzke, L. w.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Itay, R.; Kaminsky, B.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. f.; Lellouch, D.; Levinson, L.; Le Calloch, M.; Levy, C.; Lin, Q.; Lindemann, S.; Lindner, M.; Lopes, J. a. m.; Manfredini, A.; Marrodán Undagoitia, T.; Masbou, J.; Massoli, F. v.; Masson, D.; Mayani, D.; Meng, Y.; Messina, M.; Micheneau, K.; Miguez, B.; Molinario, A.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Orrigo, S. e. a.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Piro, M.-C.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; dos Santos, J. m. f.; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Scotto Lavina, L.; Selvi, M.; Shagin, P.; Silva, M.; Simgen, H.; Sivers, M. v.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C. d.; Wall, R.; Wang, H.; Weber, M.; Wei, Y.; Weinheimer, C.; Wulf, J.; Zhang, Y.. - In: PHYSICAL REVIEW D. - ISSN 2470-0010. - ELETTRONICO. - 94:12(2016), pp. 122001.1-122001.12. [10.1103/PhysRevD.94.122001]
XENON100 dark matter results from a combination of 477 live days
Aprile, E.;Aalbers, J.;Agostini, F.;Alfonsi, M.;Amaro, F. .d.;Anthony, M.;Arneodo, F.;Barrow, P.;Baudis, L.;Bauermeister, B.;Benabderrahmane, M. .l.;Berger, T.;Breur, P. .a.;Brown, A.;Brown, E.;Bruenner, S.;Bruno, G.;Budnik, R.;Bütikofer, L.;Calvén, J.;Cardoso, J. .m. .r.;Cervantes, M.;Cichon, D.;Coderre, D.;Colijn, A. .p.;Conrad, J.;Cussonneau, J. .p.;Decowski, M. .p.;de Perio, P.;Di Gangi, P.;Di Giovanni, A.;Diglio, S.;Duchovni, E.;Fei, J.;Ferella, A. .d.;Fieguth, A.;Franco, D.;Fulgione, W.;Gallo Rosso, A.;Galloway, M.;Gao, F.;Garbini, M.;Geis, C.;Goetzke, L. .w.;Greene, Z.;Grignon, C.;Hasterok, C.;Hogenbirk, E.;Itay, R.;Kaminsky, B.;Kessler, G.;Kish, A.;Landsman, H.;Lang, R. .f.;Lellouch, D.;Levinson, L.;Le Calloch, M.;Levy, C.;Lin, Q.;Lindemann, S.;Lindner, M.;Lopes, J. .a. .m.;Manfredini, A.;Marrodán Undagoitia, T.;Masbou, J.;Massoli, F. .v.;Masson, D.;Mayani, D.;Meng, Y.;Messina, M.;Micheneau, K.;Miguez, B.;Molinario, A.;Murra, M.;Naganoma, J.;Ni, K.;Oberlack, U.;Orrigo, S. .e. .a.;Pakarha, P.;Pelssers, B.;Persiani, R.;Piastra, F.;Pienaar, J.;Piro, M. C.;Plante, G.;Priel, N.;Rauch, L.;Reichard, S.;Reuter, C.;Rizzo, A.;Rosendahl, S.;Rupp, N.;dos Santos, J. .m. .f.;SARTORELLI, GABRIELLA;Scheibelhut, M.;Schindler, S.;Schreiner, J.;Schumann, M.;Scotto Lavina, L.;SELVI, MARCO;Shagin, P.;Silva, M.;Simgen, H.;Sivers, M. v.;Stein, A.;Thers, D.;Tiseni, A.;Trinchero, G.;Tunnell, C. .d.;Wall, R.;Wang, H.;Weber, M.;Wei, Y.;Weinheimer, C.;Wulf, J.;Zhang, Y.
2016
Abstract
We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A blind analysis was applied to the last run recorded between April 2013 and January 2014 prior to combining the results. The ultralow electromagnetic background of the experiment, ∼5 × 10−3 events=ðkeVee× kg × dayÞ) before electronic recoil rejection, together with the increased exposure of 48 kg × yr, improves the sensitivity. A profile likelihood analysis using an energy range of ð6.6–43.3Þ keVnr sets a limit on the elastic, spin-independent WIMP-nucleon scattering cross section for WIMP masses above 8 GeV=c2, with a minimum of 1.1×10−45 cm2 at 50GeV=c2 and 90%confidence level.We also report updated constraints on the elastic, spin-dependent WIMP-nucleon cross sections obtained with the same data. We set upper limits on the WIMP-neutron (proton) cross section with a minimum of 2.0 × 10−40 cm2 (52 × 10−40 cm2) at a WIMP mass of 50 GeV=c2, at 90% confidence level.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/599429
Citazioni
ND
112
92
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.