Difficulty with turning is a major contributor to mobility disability and falls in people with movement disorders, such as Parkinson's disease (PD). Turning often results in freezing and/or falling in patients with PD. However, asking a patient to execute a turn in the clinic often does not reveal their impairments. Continuous monitoring of turning with wearable sensors during spontaneous daily activities may help clinicians and patients determine who is at risk of falls and could benefit from preventative interventions. In this study, we show that continuous monitoring of natural turning with wearable sensors during daily activities inside and outside the home is feasible for people with PD and elderly people. We developed an algorithm to detect and characterize turns during gait, using wearable inertial sensors. First, we validate the turning algorithm in the laboratory against a Motion Analysis system and against a video analysis of 21 PD patients and 19 control (CT) subjects wearing an inertial sensor on the pelvis. Compared to Motion Analysis and video, the algorithm maintained a sensitivity of 0.90 and 0.76 and a specificity of 0.75 and 0.65, respectively. Second, we apply the turning algorithm to data collected in the home from 12 PD and 18 CT subjects. The algorithm successfully detects turn characteristics, and the results show that, compared to controls, PD subjects tend to take shorter turns with smaller turn angles and more steps. Furthermore, PD subjects show more variability in all turn metrics throughout the day and the week. © 2013 by the authors; licensee MDPI, Basel, Switzerland.

Mahmoud El-Gohary, Sean Pearson, James McNames, Martina Mancini, Fay Horak, Sabato Mellone, et al. (2014). Continuous monitoring of turning in patients with movement disability. SENSORS, 14(1), 356-369 [10.3390/s140100356].

Continuous monitoring of turning in patients with movement disability

MANCINI, MARTINA;HORAK, FAY;MELLONE, SABATO;CHIARI, LORENZO
2014

Abstract

Difficulty with turning is a major contributor to mobility disability and falls in people with movement disorders, such as Parkinson's disease (PD). Turning often results in freezing and/or falling in patients with PD. However, asking a patient to execute a turn in the clinic often does not reveal their impairments. Continuous monitoring of turning with wearable sensors during spontaneous daily activities may help clinicians and patients determine who is at risk of falls and could benefit from preventative interventions. In this study, we show that continuous monitoring of natural turning with wearable sensors during daily activities inside and outside the home is feasible for people with PD and elderly people. We developed an algorithm to detect and characterize turns during gait, using wearable inertial sensors. First, we validate the turning algorithm in the laboratory against a Motion Analysis system and against a video analysis of 21 PD patients and 19 control (CT) subjects wearing an inertial sensor on the pelvis. Compared to Motion Analysis and video, the algorithm maintained a sensitivity of 0.90 and 0.76 and a specificity of 0.75 and 0.65, respectively. Second, we apply the turning algorithm to data collected in the home from 12 PD and 18 CT subjects. The algorithm successfully detects turn characteristics, and the results show that, compared to controls, PD subjects tend to take shorter turns with smaller turn angles and more steps. Furthermore, PD subjects show more variability in all turn metrics throughout the day and the week. © 2013 by the authors; licensee MDPI, Basel, Switzerland.
2014
Mahmoud El-Gohary, Sean Pearson, James McNames, Martina Mancini, Fay Horak, Sabato Mellone, et al. (2014). Continuous monitoring of turning in patients with movement disability. SENSORS, 14(1), 356-369 [10.3390/s140100356].
Mahmoud El-Gohary; Sean Pearson; James McNames; Martina Mancini; Fay Horak; Sabato Mellone; Lorenzo Chiari
File in questo prodotto:
File Dimensione Formato  
sensors-14-00356.pdf

accesso aperto

Descrizione: Articolo sul monitoraggio dei movimenti di svolta in condizioni di vita reale
Tipo: Versione (PDF) editoriale
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione (CCBY)
Dimensione 785.16 kB
Formato Adobe PDF
785.16 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/598778
Citazioni
  • ???jsp.display-item.citation.pmc??? 98
  • Scopus 197
  • ???jsp.display-item.citation.isi??? 181
social impact