The influence of voltage duty cycle on partial discharge (PD) characteristics and endurance of inverter-fed motor insulation were investigated through tests performed on single-contact crossed enameled wires under bipolar repetitive square wave voltages with different duty cycles. The PD patterns, amplitude, repetition rate and lifetime obtained show that short duty cycles, i.e., lower than 50 μs, at 10 kHz frequency, can induce asymmetric PD patterns and reduce the probability of PD inception at falling flanks of impulsive voltages. Moreover, the endurance tests indicate that the duty cycle of the repetitive square wave voltage can affect the insulation endurance significantly. Accordingly, when performing PD inception voltage and endurance tests on insulation of inverter-fed motors, the influence of duty cycle on PD statistics and endurance should be carefully considered.

The influence of repetitive square wave voltage duty cycle on partial discharge statistics and insulation endurance / Wang, Peng; Xu, Hongying; Wang, Jian; Cavallini, Andrea. - ELETTRONICO. - (2016), pp. 7757808.274-7757808.277. (Intervento presentato al convegno 2016 International Conference on Condition Monitoring and Diagnosis, CMD 2016 tenutosi a China nel 2016) [10.1109/CMD.2016.7757808].

The influence of repetitive square wave voltage duty cycle on partial discharge statistics and insulation endurance

CAVALLINI, ANDREA
2016

Abstract

The influence of voltage duty cycle on partial discharge (PD) characteristics and endurance of inverter-fed motor insulation were investigated through tests performed on single-contact crossed enameled wires under bipolar repetitive square wave voltages with different duty cycles. The PD patterns, amplitude, repetition rate and lifetime obtained show that short duty cycles, i.e., lower than 50 μs, at 10 kHz frequency, can induce asymmetric PD patterns and reduce the probability of PD inception at falling flanks of impulsive voltages. Moreover, the endurance tests indicate that the duty cycle of the repetitive square wave voltage can affect the insulation endurance significantly. Accordingly, when performing PD inception voltage and endurance tests on insulation of inverter-fed motors, the influence of duty cycle on PD statistics and endurance should be carefully considered.
2016
CMD 2016 - International Conference on Condition Monitoring and Diagnosis
274
277
The influence of repetitive square wave voltage duty cycle on partial discharge statistics and insulation endurance / Wang, Peng; Xu, Hongying; Wang, Jian; Cavallini, Andrea. - ELETTRONICO. - (2016), pp. 7757808.274-7757808.277. (Intervento presentato al convegno 2016 International Conference on Condition Monitoring and Diagnosis, CMD 2016 tenutosi a China nel 2016) [10.1109/CMD.2016.7757808].
Wang, Peng; Xu, Hongying; Wang, Jian; Cavallini, Andrea
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/598276
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact