HVDC links with extruded cables are being widely installed in power grids. Thus, methodologies for condition evaluation for HVDC extruded cable systems are required. Partial discharge (PD) measurement is widely adopted in cable commissioning tests under AC, while there is no availability of methodologies to test PD in cables under DC. Therefore, PD measurement techniques for artificially-defected cable models under DC stress are investigated in this paper, and obtained PD characteristics are compared with those under AC stress. It is concluded that the PD test under DC voltage could have a potential for condition evaluation/monitoring, once various problems related to their measurement on field would be solved.

AC and DC partial discharge measurements on defective cables / Takahashi, Toshihiro; Wibowo, Arief Setyo; Cavallini, Andrea; Montanari, GIAN CARLO; Boyer, Ludovic; Luton, Marie Helene; Mirebeau, Pierre. - ELETTRONICO. - (2016), pp. 7548617.375-7548617.378. (Intervento presentato al convegno 34th Electrical Insulation Conference, EIC 2016 tenutosi a CANADA nel 2016) [10.1109/EIC.2016.7548617].

AC and DC partial discharge measurements on defective cables

TAKAHASHI, TOSHIHIRO;CAVALLINI, ANDREA;MONTANARI, GIAN CARLO;
2016

Abstract

HVDC links with extruded cables are being widely installed in power grids. Thus, methodologies for condition evaluation for HVDC extruded cable systems are required. Partial discharge (PD) measurement is widely adopted in cable commissioning tests under AC, while there is no availability of methodologies to test PD in cables under DC. Therefore, PD measurement techniques for artificially-defected cable models under DC stress are investigated in this paper, and obtained PD characteristics are compared with those under AC stress. It is concluded that the PD test under DC voltage could have a potential for condition evaluation/monitoring, once various problems related to their measurement on field would be solved.
2016
34th Electrical Insulation Conference, EIC 2016
375
378
AC and DC partial discharge measurements on defective cables / Takahashi, Toshihiro; Wibowo, Arief Setyo; Cavallini, Andrea; Montanari, GIAN CARLO; Boyer, Ludovic; Luton, Marie Helene; Mirebeau, Pierre. - ELETTRONICO. - (2016), pp. 7548617.375-7548617.378. (Intervento presentato al convegno 34th Electrical Insulation Conference, EIC 2016 tenutosi a CANADA nel 2016) [10.1109/EIC.2016.7548617].
Takahashi, Toshihiro; Wibowo, Arief Setyo; Cavallini, Andrea; Montanari, GIAN CARLO; Boyer, Ludovic; Luton, Marie Helene; Mirebeau, Pierre
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/598245
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 10
social impact