The double-stack Multigap Resistive Plate Chamber (MRPC) is the detector chosen for the large time-of-flight array of the ALICE experiment at CERN LHC. The system has to cover an area of 160 m2 and will consist of 1638 of such a detector. In this paper the quality assurance tests for mass production of MRPCs are described, together with the results of the tests over a sample of 18 detectors performed at the PS facility at CERN. © Società Italiana di Fisica.
Alici, A. (2004). First results from the MRPC production for the ALICE TOF system. IL NUOVO CIMENTO DELLA SOCIETÀ ITALIANA DI FISICA. C, GEOPHYSICS AND SPACE PHYSICS, 27(5), 403-412 [10.1393/ncc/i2005-10013-9].
First results from the MRPC production for the ALICE TOF system
ALICI, ANDREA
2004
Abstract
The double-stack Multigap Resistive Plate Chamber (MRPC) is the detector chosen for the large time-of-flight array of the ALICE experiment at CERN LHC. The system has to cover an area of 160 m2 and will consist of 1638 of such a detector. In this paper the quality assurance tests for mass production of MRPCs are described, together with the results of the tests over a sample of 18 detectors performed at the PS facility at CERN. © Società Italiana di Fisica.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.