Crescent Shaped Braces, CSBs, are steel hysteretic devices which, thanks to their geometrical configuration, are characterized by an enhanced seismic behavior that makes them a promising alternative to conventional diagonal steel braces and other seismic devices such as Buckling Resisting Braces and Scorpions. The present work reports the results of the first experimental campaign devoted to assess the cyclic experimental behavior of CSBs. The main goals of the experimental campaign are: (i) to verify/compare the effectiveness of design formulas for the seismic design of CSB introduced by the authors in a previous research work and the predictions of a simplified non-linear model in terms of force-displacement envelop response; (ii) to assess the experimental non-linear cyclic behavior in terms of ductility capacity, energy dissipation capacity, failures.

Experimental tests on Crescent Shaped Braces hysteretic devices / Palermo, Michele; Pieraccini, Luca; Dib, Antoine; Silvestri, Stefano; Trombetti, Tomaso. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - ELETTRONICO. - 144:(2017), pp. S0141029617313305.185-S0141029617313305.200. [10.1016/j.engstruct.2017.04.034]

Experimental tests on Crescent Shaped Braces hysteretic devices

PALERMO, MICHELE;PIERACCINI, LUCA
;
DIB, ANTOINE;SILVESTRI, STEFANO;TROMBETTI, TOMASO
2017

Abstract

Crescent Shaped Braces, CSBs, are steel hysteretic devices which, thanks to their geometrical configuration, are characterized by an enhanced seismic behavior that makes them a promising alternative to conventional diagonal steel braces and other seismic devices such as Buckling Resisting Braces and Scorpions. The present work reports the results of the first experimental campaign devoted to assess the cyclic experimental behavior of CSBs. The main goals of the experimental campaign are: (i) to verify/compare the effectiveness of design formulas for the seismic design of CSB introduced by the authors in a previous research work and the predictions of a simplified non-linear model in terms of force-displacement envelop response; (ii) to assess the experimental non-linear cyclic behavior in terms of ductility capacity, energy dissipation capacity, failures.
2017
Experimental tests on Crescent Shaped Braces hysteretic devices / Palermo, Michele; Pieraccini, Luca; Dib, Antoine; Silvestri, Stefano; Trombetti, Tomaso. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - ELETTRONICO. - 144:(2017), pp. S0141029617313305.185-S0141029617313305.200. [10.1016/j.engstruct.2017.04.034]
Palermo, Michele; Pieraccini, Luca; Dib, Antoine; Silvestri, Stefano; Trombetti, Tomaso
File in questo prodotto:
File Dimensione Formato  
PP_Experimental tests on Crescent.pdf

Open Access dal 09/05/2019

Tipo: Postprint
Licenza: Licenza per Accesso Aperto. Creative Commons Attribuzione - Non commerciale - Non opere derivate (CCBYNCND)
Dimensione 1.66 MB
Formato Adobe PDF
1.66 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/594047
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 23
social impact