Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
CRIS Current Research Information System
We report on the measurement of the two-neutrino double-beta decay half-life of 130Te with the CUORE-0 detector. From an exposure of 33.4 kg year of TeO2, the half-life is determined to be T1/22ν = [8.2 ± 0.2 (stat.) ± 0.6 (syst.)] × 1020 year. This result is obtained after a detailed reconstruction of the sources responsible for the CUORE-0 counting rate, with a specific study of those contributing to the 130Te neutrinoless double-beta decay region of interest.
Alduino, C., Alfonso, K., Artusa, D.R., Avignone, F.T., Azzolini, O., Banks, T.I., et al. (2017). Measurement of the two-neutrino double-beta decay half-life of 130 Te with the CUORE-0 experiment. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 77(1), 1-18 [10.1140/epjc/s10052-016-4498-6].
Measurement of the two-neutrino double-beta decay half-life of 130 Te with the CUORE-0 experiment
Alduino, C.;Alfonso, K.;Artusa, D. R.;Avignone, F. T.;Azzolini, O.;Banks, T. I.;Bari, G.;Beeman, J. W.;Bellini, F.;Bersani, A.;Biassoni, M.;Brofferio, C.;Bucci, C.;Camacho, A.;Caminata, A.;Canonica, L.;Cao, X. G.;Capelli, S.;Cappelli, L.;Carbone, L.;Cardani, L.;Carniti, P.;Casali, N.;Cassina, L.;Chiesa, D.;Chott, N.;Clemenza, M.;Copello, S.;Cosmelli, C.;Cremonesi, O;Creswick, R. J.;Cushman, J. S.;D’Addabbo, A.;Dafinei, I.;Davis, C. J.;Dell’Oro, S.;DENINNO, MARIA MADDALENA;Di Domizio, S.;Di Vacri, M. L.;Drobizhev, A.;Fang, D. Q.;Faverzani, M.;Feintzeig, J.;Fernandes, G.;Ferri, E.;Ferroni, F.;Fiorini, E.;Franceschi, M. A.;Freedman, S. J.;Fujikawa, B. K.;Giachero, A.;Gironi, L.;Giuliani, A.;Gladstone, L.;Gorla, P.;Gotti, C.;Gutierrez, T. D.;Haller, E. E.;Han, K.;Hansen, E.;Heeger, K. M.;Hennings Yeomans, R.;Hickerson, K. P.;Huang, H. Z.;Kadel, R.;Keppel, G.;Kolomensky, Y.u. G.;Leder, A.;Ligi, C.;Lim, K. E.;Liu, X.;Ma, Y. G.;Maino, M.;Marini, L.;Martinez, M.;Maruyama, R. H.;Mei, Y.;MOGGI, NICCOLO';Morganti, S.;Mosteiro, P. J.;Napolitano, T.;Nones, C.;Norman, E. B.;Nucciotti, A.;O’Donnell, T.;Orio, F.;Ouellet, J. L.;Pagliarone, C. E.;Pallavicini, M.;Palmieri, V.;Pattavina, L.;Pavan, M.;Pessina, G.;Pettinacci, V.;Piperno, G.;Pira, C.;Pirro, S.;Pozzi, S.;Previtali, E.;Rosenfeld, C.;Rusconi, C.;Sangiorgio, S.;Santone, D.;Scielzo, N. D.;Singh, V.;Sisti, M.;Smith, A. R.;Taffarello, L.;Tenconi, M.;Terranova, F.;Tomei, C.;Trentalange, S.;Vignati, M.;Wagaarachchi, S. L.;Wang, B. S.;Wang, H. W.;Wilson, J.;Winslow, L. A.;Wise, T.;Woodcraft, A.;Zanotti, L.;Zhang, G. Q.;Zhu, B. X.;Zimmermann, S.;ZUCCHELLI, STEFANO
2017
Abstract
We report on the measurement of the two-neutrino double-beta decay half-life of 130Te with the CUORE-0 detector. From an exposure of 33.4 kg year of TeO2, the half-life is determined to be T1/22ν = [8.2 ± 0.2 (stat.) ± 0.6 (syst.)] × 1020 year. This result is obtained after a detailed reconstruction of the sources responsible for the CUORE-0 counting rate, with a specific study of those contributing to the 130Te neutrinoless double-beta decay region of interest.
Alduino, C., Alfonso, K., Artusa, D.R., Avignone, F.T., Azzolini, O., Banks, T.I., et al. (2017). Measurement of the two-neutrino double-beta decay half-life of 130 Te with the CUORE-0 experiment. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 77(1), 1-18 [10.1140/epjc/s10052-016-4498-6].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/592892
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
96
84
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.