Background Contemporary scores for estimating perioperative death have been proposed to also predict also long-term death. The aim of the study was to evaluate the performance of the updated European System for Cardiac Operative Risk Evaluation II, The Society of Thoracic Surgeons Predicted Risk of Mortality score, and the Age, Creatinine, Left Ventricular Ejection Fraction score for predicting long-term mortality in a contemporary cohort of isolated aortic valve replacement (AVR). We also sought to develop for each score a simple algorithm based on predicted perioperative risk to predict long-term survival. Methods Complete data on 1,444 patients who underwent isolated AVR in a 7-year period were retrieved from three prospective institutional databases and linked with the Italian Tax Register Information System. Data were evaluated with performance analyses and time-to-event semiparametric regression. Results Survival was 83.0% ± 1.1% at 5 years and 67.8 ± 1.9% at 8 years. Discrimination and calibration of all three scores both worsened for prediction of death at 1 year and 5 years. Nonetheless, a significant relationship was found between long-term survival and quartiles of scores (p < 0.0001). The estimated perioperative risk by each model was used to develop an algorithm to predict long-term death. The hazard ratios for death were 1.1 (95% confidence interval, 1.07 to 1.12) for European System for Cardiac Operative Risk Evaluation II, 1.34 (95% CI, 1.28 to 1.40) for the Society of Thoracic Surgeons score, and 1.08 (95% CI, 1.06 to 1.10) for the Age, Creatinine, Left Ventricular Ejection Fraction score. Conclusions The predicted risk generated by European System for Cardiac Operative Risk Evaluation II, The Society of Thoracic Surgeons score, and Age, Creatinine, Left Ventricular Ejection Fraction scores cannot also be considered a direct estimate of the long-term risk for death. Nonetheless, the three scores can be used to derive an estimate of long-term risk of death in patients who undergo isolated AVR with the use of a simple algorithm.

Barili, F., Pacini, D., D'Ovidio, M., Ventura, M., Alamanni, F., DI BARTOLOMEO, R., et al. (2016). Reliability of Modern Scores to Predict Long-Term Mortality After Isolated Aortic Valve Operations. ANNALS OF THORACIC SURGERY, 101(2), 599-605 [10.1016/j.athoracsur.2015.07.088].

Reliability of Modern Scores to Predict Long-Term Mortality After Isolated Aortic Valve Operations

PACINI, DAVIDE;DI BARTOLOMEO, ROBERTO;DAVOLI, MARINA;PERUCCI, CARLO;
2016

Abstract

Background Contemporary scores for estimating perioperative death have been proposed to also predict also long-term death. The aim of the study was to evaluate the performance of the updated European System for Cardiac Operative Risk Evaluation II, The Society of Thoracic Surgeons Predicted Risk of Mortality score, and the Age, Creatinine, Left Ventricular Ejection Fraction score for predicting long-term mortality in a contemporary cohort of isolated aortic valve replacement (AVR). We also sought to develop for each score a simple algorithm based on predicted perioperative risk to predict long-term survival. Methods Complete data on 1,444 patients who underwent isolated AVR in a 7-year period were retrieved from three prospective institutional databases and linked with the Italian Tax Register Information System. Data were evaluated with performance analyses and time-to-event semiparametric regression. Results Survival was 83.0% ± 1.1% at 5 years and 67.8 ± 1.9% at 8 years. Discrimination and calibration of all three scores both worsened for prediction of death at 1 year and 5 years. Nonetheless, a significant relationship was found between long-term survival and quartiles of scores (p < 0.0001). The estimated perioperative risk by each model was used to develop an algorithm to predict long-term death. The hazard ratios for death were 1.1 (95% confidence interval, 1.07 to 1.12) for European System for Cardiac Operative Risk Evaluation II, 1.34 (95% CI, 1.28 to 1.40) for the Society of Thoracic Surgeons score, and 1.08 (95% CI, 1.06 to 1.10) for the Age, Creatinine, Left Ventricular Ejection Fraction score. Conclusions The predicted risk generated by European System for Cardiac Operative Risk Evaluation II, The Society of Thoracic Surgeons score, and Age, Creatinine, Left Ventricular Ejection Fraction scores cannot also be considered a direct estimate of the long-term risk for death. Nonetheless, the three scores can be used to derive an estimate of long-term risk of death in patients who undergo isolated AVR with the use of a simple algorithm.
2016
Barili, F., Pacini, D., D'Ovidio, M., Ventura, M., Alamanni, F., DI BARTOLOMEO, R., et al. (2016). Reliability of Modern Scores to Predict Long-Term Mortality After Isolated Aortic Valve Operations. ANNALS OF THORACIC SURGERY, 101(2), 599-605 [10.1016/j.athoracsur.2015.07.088].
Barili, Fabio; Pacini, Davide; D'Ovidio, Mariangela; Ventura, Martina; Alamanni, Francesco; DI BARTOLOMEO, Roberto; Grossi, Claudio; Davoli, Marina; F...espandi
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/591470
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 14
social impact