Objective. To assess the findings of temporal artery colour duplex sonography (CDS) in GCA characterized by a histological pattern of periadventitial small vessel vasculitis (SVV) and/or vasa vasorum vasculitis (VVV) and compare it with those observed in classic GCA with transmural vasculitis.Methods. We studied 30 patients with SVV and/or VVV, 63 patients with classic GCA and 67 biopsy-negative patients identified over a 9-year period. CDS of the temporal arteries was performed in all patients by one ultrasonographer. Temporal artery biopsy was used as the reference standard. Sensitivities, specificities and likelihood ratios (LRs) were calculated.Results. The frequency of the halo sign on CDS was significantly lower in the patients with SVV and/or VVV compared with those with classic GCA (20% vs 82.5%, P = 0.0001). The halo sign had a sensitivity of only 20% (95% CI 8.4, 39.1%) and a specificity of 80.6% (95% CI 68.7, 88.9%) for the diagnosis of SVV and/or VVV. The negative LR was 0.992 (CI 0.824, 1.195), and the positive LR was 1.030 (CI 0.433, 2.451). The halo sign for the diagnosis of biopsy-proven classic GCA had a higher sensitivity of 82.5% (CI 70.5, 90.5%), the same specificity of 80.6% (CI 68.7, 88.9%) and a higher positive LR (4.253; CI 2.577, 7.021).Conclusion. The halo sign is infrequently found in GCA characterized by a histological pattern of SVV and/or VVV. This limits the sensitivity of CDS in correctly identifying patients with GCA. © The Author 2013. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved.

Comparison between colour duplex sonography findings and different histological patterns of temporal artery / Muratore, Francesco; Boiardi, Luigi; Restuccia, Giovanna; Macchioni, Pierluigi; Pazzola, Giulia; Nicolini, Alberto; Germanò, Giuseppe; Possemato, Niccolò; Cavazza, Alberto; Cavuto, Silvio; Cimino, Luca; Pipitone, Nicolò; Catanoso, Mariagrazia; Addimanda, Olga; Salvarani, Carlo. - In: RHEUMATOLOGY. - ISSN 1462-0324. - ELETTRONICO. - 52:12(2013), pp. ket258.2268-ket258.2274. [10.1093/rheumatology/ket258]

Comparison between colour duplex sonography findings and different histological patterns of temporal artery

ADDIMANDA, OLGA;
2013

Abstract

Objective. To assess the findings of temporal artery colour duplex sonography (CDS) in GCA characterized by a histological pattern of periadventitial small vessel vasculitis (SVV) and/or vasa vasorum vasculitis (VVV) and compare it with those observed in classic GCA with transmural vasculitis.Methods. We studied 30 patients with SVV and/or VVV, 63 patients with classic GCA and 67 biopsy-negative patients identified over a 9-year period. CDS of the temporal arteries was performed in all patients by one ultrasonographer. Temporal artery biopsy was used as the reference standard. Sensitivities, specificities and likelihood ratios (LRs) were calculated.Results. The frequency of the halo sign on CDS was significantly lower in the patients with SVV and/or VVV compared with those with classic GCA (20% vs 82.5%, P = 0.0001). The halo sign had a sensitivity of only 20% (95% CI 8.4, 39.1%) and a specificity of 80.6% (95% CI 68.7, 88.9%) for the diagnosis of SVV and/or VVV. The negative LR was 0.992 (CI 0.824, 1.195), and the positive LR was 1.030 (CI 0.433, 2.451). The halo sign for the diagnosis of biopsy-proven classic GCA had a higher sensitivity of 82.5% (CI 70.5, 90.5%), the same specificity of 80.6% (CI 68.7, 88.9%) and a higher positive LR (4.253; CI 2.577, 7.021).Conclusion. The halo sign is infrequently found in GCA characterized by a histological pattern of SVV and/or VVV. This limits the sensitivity of CDS in correctly identifying patients with GCA. © The Author 2013. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved.
2013
Comparison between colour duplex sonography findings and different histological patterns of temporal artery / Muratore, Francesco; Boiardi, Luigi; Restuccia, Giovanna; Macchioni, Pierluigi; Pazzola, Giulia; Nicolini, Alberto; Germanò, Giuseppe; Possemato, Niccolò; Cavazza, Alberto; Cavuto, Silvio; Cimino, Luca; Pipitone, Nicolò; Catanoso, Mariagrazia; Addimanda, Olga; Salvarani, Carlo. - In: RHEUMATOLOGY. - ISSN 1462-0324. - ELETTRONICO. - 52:12(2013), pp. ket258.2268-ket258.2274. [10.1093/rheumatology/ket258]
Muratore, Francesco; Boiardi, Luigi; Restuccia, Giovanna; Macchioni, Pierluigi; Pazzola, Giulia; Nicolini, Alberto; Germanò, Giuseppe; Possemato, Niccolò; Cavazza, Alberto; Cavuto, Silvio; Cimino, Luca; Pipitone, Nicolò; Catanoso, Mariagrazia; Addimanda, Olga; Salvarani, Carlo
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/590941
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 43
  • ???jsp.display-item.citation.isi??? 45
social impact