This paper discusses the results of an experimental campaign that led to the characterization of flanking transmission in CLT structures with different connection systems. The vibration reduction indices Kij were measured in accordance with the ISO 10848-1 standard in order to provide data suitable to calculate the apparent reduction index according to the EN 12354-1 standard. The research explored several vertical and horizontal junctions on which different number and the type of screws and plates, different CLT panels, and resilient materials at the wall-floor junction were tested. The results show that the Kij along different transmission paths have a specific trends in frequency that depend on the fastening system and the mutual connection of the panels. Moreover, the analysis shows great discrepancies among measurements performed on CLT panels provided by different manufacturers. The results call for a deeper investigation concerning the mechanical/acoustical characterization of the panels.

Barbaresi, L., Morandi, F., Garai, M., Speranza, A. (2016). Experimental measurements of flanking transmission in CLT structures. PROCEEDINGS OF MEETINGS ON ACOUSTICS, 28, 1-10 [10.1121/2.0000433].

Experimental measurements of flanking transmission in CLT structures

BARBARESI, LUCA;MORANDI, FEDERICA;GARAI, MASSIMO;
2016

Abstract

This paper discusses the results of an experimental campaign that led to the characterization of flanking transmission in CLT structures with different connection systems. The vibration reduction indices Kij were measured in accordance with the ISO 10848-1 standard in order to provide data suitable to calculate the apparent reduction index according to the EN 12354-1 standard. The research explored several vertical and horizontal junctions on which different number and the type of screws and plates, different CLT panels, and resilient materials at the wall-floor junction were tested. The results show that the Kij along different transmission paths have a specific trends in frequency that depend on the fastening system and the mutual connection of the panels. Moreover, the analysis shows great discrepancies among measurements performed on CLT panels provided by different manufacturers. The results call for a deeper investigation concerning the mechanical/acoustical characterization of the panels.
2016
Barbaresi, L., Morandi, F., Garai, M., Speranza, A. (2016). Experimental measurements of flanking transmission in CLT structures. PROCEEDINGS OF MEETINGS ON ACOUSTICS, 28, 1-10 [10.1121/2.0000433].
Barbaresi, Luca; Morandi, Federica; Garai, Massimo; Speranza, Alice
File in questo prodotto:
Eventuali allegati, non sono esposti

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11585/584183
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 24
  • ???jsp.display-item.citation.isi??? ND
social impact